Page 2: ...Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications You are cautioned that any changes or modifications...

Page 3: ...6 Wiring the Fault Alarm Contact 14 2 1 7 Cabling 15 2 1 7 1 Installing the SFP transceiver 15 2 1 7 Redundancy Overview 19 2 2 MOUNTING INSTALLATION 20 2 2 1 DIN Rail mounting 20 2 2 2 Wall Mount Plate Mounting 22 3 APPLICAITON 23 4 SWITCH OPERATION 25 4 1 ADDRESS TABLE 25 4 2 LEARNING 25 4 3 FORWARDING FILTERING 25 4 4 STORE AND FORWARD 25 4 5 AUTO NEGOTIATION 26 5 TROUBLESHOOTING 27 6 CABLE CON...

Page 4: ...carton including the original packing material and use them again to repack the product in case there is a need to return it to us for repair 1 2 How to Use This Manual This Industrial Gigabit PoE Switch User Manual is structured as follows Chapter 2 Installation The chapter explains the feature functionality and the physical installation of the Industrial Gigabit PoE Switch Chapter 3 Application ...

Page 5: ...Prevents packet loss with back pressure Half Duplex and IEEE 802 3x PAUSE frame flow control Full Duplex Automatic address learning and address aging Industrial Case Installation IP30 aluminum metal case protection DIN Rail and Wall Mount Design 48V DC redundant power with polarity reverse protect function and connective removable terminal block for master and slave power Supports EFT protection 6...

Page 6: ...ystem and Power Green DC Power 1 Green DC Power 2 Green Power Fault 2 x LED for Per Copper Port Port 1 Port 4 Green 1000 LNK ACT Orange 100 LNK ACT Orange PoE In use 1 x LED for Per mini GBIC interface MC352 4P 2SPort 5 and Port 6 Green LNK ACT 4 x LED for PoE Power Usage W Orange 30 60 90 and 120W ESD Protection 6KV DC EFT Protection 6KV DC Enclosure IP30 type metal case Installation DIN rail kit...

Page 7: ...DC 275mA Max 15 4 watts IEEE 802 3af Per port 52V DC 535mA Max 30 watts IEEE 802 3at Power Pin Assignment 1 2 3 6 Max number of Class 4 PD 4 Standards Conformance Standards Compliance IEEE 802 3 Ethernet 10Base T IEEE 802 3u Fast Ethernet 100Base TX IEEE 802 3ab Gigabit Ethernet 1000Base T IEEE 802 3z Gigabit Ethernet 1000Base SX LX IEEE 802 3x Full Duplex Flow Control IEEE 802 3at Power over Ethe...

Page 8: ... 8 1 5 Physical Dimensions MC352 4P 2S Industrial Gigabit PoE Switch dimensions W x D x H 161 x 107 x 72 mm ...

Page 9: ...e current conventional 802 3af PoE Environmentally Hardened Design The MC352 4P 2S is equipped with rugged IP30 metal case for easy deployment in heavy Industrial demanding environments With IP30 metal case protection the MC352 4P 2S provide a high level of immunity against electromagnetic interference and heavy electrical surges which are usually found on plant floors or in curb side traffic cont...

Page 10: ...Figure 2 1 MC352 4P 2S Front Panels PoE Power Usage LED The front panel of the Industrial Gigabit PoE Switch has four LEDs which indicate PoE Power Usages W of 30W 60W 90W and 120W With these LED indications you can monitor current PoE power in use status of Industrial Gigabit PoE Switch easily and efficiently ...

Page 11: ...ver that port Green OFF indicates that the Switch is inactively sending or receiving data over that port Light indicates the Switch is successfully connecting to the network at 10Mbps or 100Mbps Blink indicates that the Switch is actively sending or receiving data over that port LNK ACT Orange OFF indicates that the Switch is inactively sending or receiving data over that port Light indicates the ...

Page 12: ...X 30 30W LED light 55 X 60 60W LED flash X 60 60W LED light 85 X 90 90W LED flash X 90 90W LED light 100 X 115 120W LED flash 115 X 120 120W LED flash fast X 120 120W LED light 2 1 4 Switch Upper Panel The upper panel of the Industrial Gigabit PoE Switch consists of one terminal block connector within two DC power inputs Figure 2 2 shows the upper panel of the Switch Figure 2 2 shows upper panel o...

Page 13: ...input Please follow the steps below to insert the power wire 1 Insert positive negative DC power wires into contacts 1 and 2 for POWER 1 or 5 and 6 for POWER 2 V1 V1 V2 V2 2 Tighten the wire clamp screws for preventing the wires from loosening 1 2 3 4 5 6 Power 1 Fault Power 2 The wire gauge for the terminal block should be in the range between 12 and 24 AWG ...

Page 14: ...ct the fault status of the power failure or port link failure available for managed model and then forms an open circuit The following illustration shows an application example for wiring the fault alarm contacts 1 2 3 4 5 6 1 The wire gauge for the terminal block should be in the range between 12 24 AWG 2 Alarm relay circuit accepts up to 30V max 3A currents Insert the wires into the fault alarm ...

Page 15: ...works can use Cat 3 4 5 or 1000Base T uses 5 5e 6 UTP see table below Maximum distance is 100 meters 328 feet The 100Base FX 1000Base SX LX SFP slot is used as LC connector with optional SFP module Please see table below and know more about the cable s specification Port Type Cable Type Connector 10Base T Cat 3 4 5 2 pair RJ 45 100Base TX Cat 5 UTP 2 pair RJ 45 1000Base T Cat 5 5e 6 UTP 4 pair RJ ...

Page 16: ...nnector Single Mode Gigabit 2 fiber 1310nm 1310nm 30km Hardened 40 75 C S35 2SLC 70 SFP LC Connector Single Mode Gigabit 2 fiber 1550nm 1550nm 70km Hardened 40 75 C S20 1SLC A 20 SFP LC Connector Single Mode 10 100 Fast Ethernet 1 fiber 1310nm 1550nm 20km A End S20 1SLC B 20 SFP LC Connector Single Mode 10 100 Fast Ethernet 1 fiber 1310nm 1550nm 20km B End S20 2MLC 2 SFP LC Connector Multi Mode 10...

Page 17: ...bit 100m 1000Base SX LX Before connecting with switches workstation or media converter please do the following steps 1 With 1000Base X Fiber Speed please set the DIP Switch of SFP Port 5 or Port 6 to the OFF position 2 Make sure both sides of the SFP transceivers are with the same media type for example 1000Base SX to 1000Base SX 1000Base LX to 1000Base LX 3 Check whether the fiber optic cable typ...

Page 18: ...ide being the male duplex LC connector type Connecting the fiber cable 1 Insert the duplex LC connector on the network cable into the SFP transceiver 2 Connect the other end of the cable to a device switches with SFP installed to fiber NIC on a workstation or a media converter 3 Check the LNK ACT LED of the SFP slot of the switch converter Ensure that the SFP transceiver is operating correctly 2 1...

Page 19: ...ndustrial Gigabit Ethernet Switch 2 1 7 Redundancy Overview The MC352 4P 2S Industrial Gigabit PoE Switch provides rapid fiber redundancy of link for highly critical Ethernet applications The redundant mode supports auto recover function If the destination port of a packet is link down it forwards the packet to the other port of the backup pair The following figure shows the redundant function Fig...

Page 20: ... perform the procedures in the order being presented In the installation steps below this Manual uses IGS 801 IFS 8 Port Industrial Gigabit Switch as the example However the steps for IFS Industrial Gigabit PoE Switch are similar 2 2 1 DIN Rail mounting The DIN Rail is screwed on the Industrial Gigabit Ethernet Switch when out of factory When needed to replace the wall mount application with the D...

Page 21: ...htly insert the bottom of the switch into the track Step 3 Check if the DIN Rail is tightly on the track Step 4 Please refer to the following procedures to remove the Industrial Gigabit Ethernet Switch from the track ...

Page 22: ...from the Industrial Gigabit Ethernet Switch loose the screws to remove the DIN Rail Step 2 Place the wall mount plate on the rear panel of the Industrial Gigabit Ethernet Switch Step 3 Use the screws to screw the wall mount plate on the Industrial Gigabit Ethernet Switch Step 4 Use the hook holes at the corners of the wall mount plate to hang the Industrial Gigabit Ethernet Switch on the wall Step...

Page 23: ... 23 3 Applications In this paragraph we will describe how to install Industrial Gigabit PoE Switch and the installation points Industrial Operating Environment Harsh Climate ...

Page 24: ...ut The power LED on the Industrial Gigabit PoE Switch will light up Please refer to the LED Indicators section for the functions of LED lights Step 5 Prepare the twisted pair straight through Category 5 cable for Ethernet connection Step 6 Insert one side of Category 5 cable into the Industrial Gigabit PoE Switch Ethernet port RJ 45 port and the other side of category 5 cable to the network device...

Page 25: ... if the destination address is located at the same port with this packet that comes in then this packet will be filtered thereby increasing the network throughput and availability 4 4 Store and Forward Store and Forward is one type of packet forwarding techniques A Store and Forward Industrial Gigabit PoE Switch stores the incoming frame in an internal buffer and does the complete error checking b...

Page 26: ... have built in Auto negotiation This technology automatically sets the best possible bandwidth when a connection is established with another network device usually at Power On or Reset This is done by detecting the modes and speeds at the second of both devices that are connected and capable of Both 10Base T and 100Base TX devices can connect with the port in either Half or Full Duplex mode 1000Ba...

Page 27: ...gabit PoE Switch doesn t connect to the network Solution Check per port LED on the Industrial Gigabit PoE Switch Try another port on the Industrial Gigabit PoE Switch Make sure the cable is installed properly Make sure the cable is the right type Turn off the power After a while turn on the power again Why after my PoE PD device is connected to MC352 4P 2S it cannot power on Solution 1 Please chec...

Page 28: ...ulti mode 50 125μm or 62 5 125μm Multi mode 50 125μm or 62 5 125μm 1000Base LX 1310nm Single mode 9 125μm Wiring Distances Standard Fiber Diameter micron Modal Bandwidth MHz km Max Distance meters 1000Base SX Multi mode 62 5 62 5 50 50 100 200 400 500 220 275 500 550 Multi mode 62 5 50 50 5 4 5 550 1000Base LX Single mode 9 N A 5000 1000Base ZX Single mode 9 N A 70 000 Notice The Single mode port ...

Page 29: ...r A 2 Switch s RJ 45 Pin Assignments 1000Mbps 1000Base T Contact MDI MDI X 1 BI_DA BI_DB 2 BI_DA BI_DB 3 BI_DB BI_DA 4 BI_DC BI_DD 5 BI_DC BI_DD 6 BI_DB BI_DA 7 BI_DD BI_DC 8 BI_DD BI_DC 10 100Mbps 10 100Base TX RJ 45 Connector pin assignment Contact MDI Media Dependant Interface MDI X Media Dependant Interface Cross 1 Tx transmit Rx receive ...

Page 30: ... standard UTP STP cable and each wire is color coded The following shows the pin allocation and color of straight cable and crossover cable connection Straight Cable SIDE 1 SIDE2 SIDE 1 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 SIDE 2 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown...

Page 31: ... White Blue 6 Green 7 White Brown 8 Brown 1 White Green 2 Green 3 White Orange 4 Blue 5 White Blue 6 Orange 7 White Brown 8 Brown Figure A 1 Straight Through and Crossover Cable Please make sure your connected cables are with the same pin assignment and color as the above picture before deploying the cables into your network ...