HLP-A100 Series Operating Manual
HLP-A100 Series
-
98
-
Description of Choice: Point A as shown in the figure is the analog value that
corresponds to a setpoint that equals 0. It is calculated via analog low
、
high values and low
、
high references. UAB=UAC=C06.18/2
Option: [0] Voltage mode;
[1] Current mode;
Function: Select the input to be present on analog input VI.
C06.19
Function Description
Range
Unit
Default Setting
Terminal VI Mode
0~1
0
Function: This reference signal should correspond to minmum reference/
feedback value set in C06.24.
C06.2* Analog Input 2
C06.20
Function Description
Range
Unit
Default Setting
Terminal AI Low Voltage 0.00~9.99
V
0.07
Function: This reference signal should correspond to max. reference/feedback
value set in C06.25.
C06.21
Function Description
Range
Unit
Default Setting
Terminal AI High Voltage 0.01~10.00
V
10.00
Function: This reference signal should correspond to min. reference /
feedback value set in C06.24.
C06.22
Function Description
Range
Unit
Default Setting
Terminal AI Low Current 0.00~19.99 mA
0.14