7.13 Simple PLC
7.13.1 Order Execution
The following figure shows order execution mode of four events/actions:
Use order execution to achieve Eight-speed Internal Control Function :
Parameter Ref. Function Parameter Ref.
Function
C03.10[0]
20
Preset
reference 0
C13.20[0]
5
Timer 0 time
C03.10[1]
-40
Preset
reference 1
C13.20[1]
10
Timer 1 time
C03.10[2]
50
Preset
reference 2
C13.20[2]
8
Timer 2 time
C03.10[3]
100
Preset
reference 3
C13.20[3]
12
Timer 3 time
C03.10[4]
-100
Preset
reference 4
C13.20[4]
15
Timer 4 time
C03.10[5]
-20
Preset
reference 5
C13.20[5]
7
Timer 5 time