HLP-A100 Series
HLP-A100 Series Operating Manual
-
149
-
C30.32 Function Description
Range
Unit
Default Setting
Length Setting
0.000~60.000
km
10.000
Function: When wobble length reaches to the value set in this parameter,
Setting Length Reached Action becomes active.
C30.33 Function Description
Range
Unit
Default Setting
Length Reach Mode
0~1
0
Option: [0] : No action;
[1]: Stop, the drive stops.
Function: If setting length reached, one of the selection in this parameter
will be operated.
C30.38 Function Description
Range
Unit
Default Setting
Wobble Restore Mode
0~1
0
Option: [0]: Dcenter stage;
[1]: Dwell stage;
Function: When Auto is selected as Wobble cycle start mode (C30.00=0), if [0]
is selected, drive will ramp to centre f requency according to active
ramp time if wobble restore command is active; If [1] is selected,
drive will ramp to dwell f requency according to active ramp time
if wobble restore command is active; When Manuel is selected as
Wobble cycle start mode(C30.00=1), if wobble restore command
is active, drive will ramp to centre f requency according to active
ramp time.
C30.39 Function Description
Range
Unit
Default Setting
Wobble Stage Store
0~3
0
Option: [0]: Disable;
[1]: Power stop save;
[2]: Power saves;
[3]: Stop saves;
Function: This parameter is used to select in which way the wobble f unction
saves the information.