HLP-A100 Series
HLP-A100 Series Operating Manual
-
29
-
Item Parameter
No.
Function
Description
Setting range
Unit
Default
setting
Page
No.
Pa
ra
m
ete
r G
rou
p01
: L
oa
d/m
oto
r
*C01.01 Motor Control
Principle
0: U/F; 1: VCC+;
1
59
*C01.03 Torque
Characteristics
0: Constant torque;
1: Mutative; 3: Energy
optim;
0
59
*C01.07
Application
Configuration
Mode
0: No Function;
1: Wobble Function;
2: Cascade Control;
3: Winder Function;
0
60
*C01.20 Motor Power
[kW][HP]
Dep.on motor data
kW
*
60
*C01.22 Motor Voltage
(Um.n)
50~1000
V
*
60
*C01.23
Motor
Frequency
(f m.n)
20~400
Hz
*
61
*C01.24 Motor
Current(Im.n) Dep.on motor data
A
*
61
*C01.25
Motor
Nominal
Speed(nm.n)
100~9999
rpm
*
61
*C01.29
Automatic
Motor
Adaptation
(AMA)
0: Off; 1: Enabled
Complete AMA;
2: Enable Reduced
AMA;
0
61
*C01.30
Stator
Resistance
(Rs)
Dep.on motor data
Ω
*
62
*C01.33
Stator
Leakage
Reactance
(XI)
Dep.on motor data
Ω
*
62
*C01.35
Main
Reactance
(Xh)
Dep.on motor data
Ω
*
62
*C01.39 Motor poles
2~100
P
4
62
*C01.42 Motor Cable
Length
0~150
m
50
62