Part Number

Port One - Twisted-Pair

Port Two - Coax

The Transition Networks J/E-CX-TBT-02
Ethernet media converter connects
10Base-T shielded or unshielded
twisted-pair copper cable to 10Base-2
coaxial copper cable.  

The J/E-CX-TBT-02 supports up to 24
daisy-chained devices on one coax
segment per twisted-pair segment. 

User’s Guide

J/E-CX-TBT-02  

Stand-Alone Media Converter
• Coax to twisted pair
• 10Base-2 to 10Base-T

Installation  . . . . . . . . . . . . . . . . . .2
Cable Specifications  . . . . . . . . . . .4
Technical Specifications  . . . . . . . .5
Troubleshooting  . . . . . . . . . . . . . .6
Contact Us  . . . . . . . . . . . . . . . . . .7

* Typical maximum cable distance.  The actual maximum cable distances are

dependent upon the physical characteristics of the network installation.

J/E-CX-TBT-02

RJ-45, 10Base-T
100 m

(328 ft)*

BNC, 10Base-2
185 m 

(610 ft)*

Summary of Contents for J/E-CX-TBT-02

Page 1: ...ned devices on one coax segment per twisted pair segment User s Guide J E CX TBT 02 Stand Alone Media Converter Coax to twisted pair 10Base 2 to 10Base T Installation 2 Cable Specifications 4 Technical Specifications 5 Troubleshooting 6 Contact Us 7 Typical maximum cable distance The actual maximum cable distances are dependent upon the physical characteristics of the network installation J E CX T...

Page 2: ...ild 10Base 2 compliant coax cable with female BNC connectors installed at both ends 2 Connect the BNC cable connector at one end of the cable to the BNC port on the media converter 3 Connect the BNC cable connector at the other end of the cable to the BNC port on the 10Base 2 compliant device CAUTION Ensure that the 10Base 2 coax cables are terminated properly at both ends In a coax thinnet instal...

Page 3: ...rk RJ 45 Pin out Pin 1 TD Pin 2 TD Pin 3 RD Pin 6 RD Use only dedicated wire pairs for the active pins e g blue white and white blue orange white and white orange etc Do not use flat or silver satin wire Crossover Cable 1 2 3 6 Straight Through Cable Twisted Pair 1 Twisted Pair 1 Twisted Pair 2 Twisted Pair 2 1 2 3 6 1 2 3 6 1 2 3 6 5 techsupport transition com Click the Transition Now link for a ...

Page 4: ...initialization process Contact Technical Support YES Contact Technical Support 6 J E CX TBT 02 24 hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 7 techsupport transition com Click the Transition Now link for a live Web chat Declaration of Conformity Name of Mfg Transition Networks 6475 City West Parkway Minneapolis MN 55344 U S A Model J E CX TBT 02 Series Media Converters P...

Page 5: ...partment of Communications Le présent appareil numérique n émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la Class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada European regulations Warning This is a Class A product In a domestic environment this product may cause radio interf...

Reviews: