Transition Networks J/E-CX-TBT-02 User Manual Download Page 3

4

J/E-CX-TBT-02 

24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600  

Cable Specifications

10Base-2 cable

Cable type: 

Stranded coaxial RG-58

Impedance:

50 

Maximum cable distance:

185 m 

(610 ft.)

Minimum cable distance:

0.5 m

(1.6 ft.)

Device placement along segment:

0.5 m intervals

Max length of any single series path:

3 segments and 2 links

Maximum number of connections:

30

10Base-T cable

Category 3

(minimum requirement)

Gauge:

24 to 22 AWG

Attenuation: 

11.5 dB/100m @ 5-10 MHz

Maximum cable distance:

100 m 

(328 ft)

Category 5 

(recommended)

Gauge:

24 to 22 AWG

Attenuation: 

22.0 dB/100m @ 100 MHz

Maximum cable distance:

100 m 

(328 ft)

Cable considerations:

• Either straight-through or crossover cable can be used. 
• Shielded (STP) or unshielded (UTP) twisted-pair cable can be used.
• Pins 1 and 2, 3 and 6 are the two active pairs in an Ethernet network.
• RJ-45 Pin-out:  Pin 1 = TD+, Pin 2 = TD-, Pin 3 = RD+, Pin 6 = RD-
• Use only dedicated wire pairs for the active pins; e.g., blue/white and

white/blue, orange/white and white/orange, etc.

• Do not use flat or silver satin wire. 

Crossover Cable

1
2

3
6

Straight-Through Cable

Twisted Pair #1

Twisted Pair #1

Twisted Pair #2

Twisted Pair #2

1
2

3
6

1
2

3
6

1
2

3
6

5

[email protected] -- Click the “Transition Now” link for a live Web chat.

Technical Specifications

For the Transition Networks Model J/E-CX-TBT-02 or equivalent.

Standards:

IEEE 802.3 

Dimensions:

1" x 2.75" x 3.7" 

(26 mm x 71 mm x 94 mm)

Weight:

6 oz 

(181 g)

approximate

Data Rate: 

10 Mb/s 

(half-duplex mode)

LEDs:

BNC/Act, TP/Act, Col, Pwr

Power Supply:

100-240VAC 50/60 Hz, 1.0A @ 5VDC 

(The external 

power supply provided with this product is UL listed 
by the power supply’s manufacturer.)

MTBF:

49,000 hours 

(MIL217F2 V5.0) (MIL-HDBK-217F)

129,000 hours 

(Bellcore7 V5.0)

Operating Temp:

0°C to 50°C 

(32° F to 122° F )

Storage Temp:

-20°C to 85°C 

(-4° F to 185° F )

Humidity:

10% to 90%, non-condensing 

Altitude:

0 to 10,000 feet

Warranty:

Lifetime

Summary of Contents for J/E-CX-TBT-02

Page 1: ...ned devices on one coax segment per twisted pair segment User s Guide J E CX TBT 02 Stand Alone Media Converter Coax to twisted pair 10Base 2 to 10Base T Installation 2 Cable Specifications 4 Technical Specifications 5 Troubleshooting 6 Contact Us 7 Typical maximum cable distance The actual maximum cable distances are dependent upon the physical characteristics of the network installation J E CX T...

Page 2: ...ild 10Base 2 compliant coax cable with female BNC connectors installed at both ends 2 Connect the BNC cable connector at one end of the cable to the BNC port on the media converter 3 Connect the BNC cable connector at the other end of the cable to the BNC port on the 10Base 2 compliant device CAUTION Ensure that the 10Base 2 coax cables are terminated properly at both ends In a coax thinnet instal...

Page 3: ...rk RJ 45 Pin out Pin 1 TD Pin 2 TD Pin 3 RD Pin 6 RD Use only dedicated wire pairs for the active pins e g blue white and white blue orange white and white orange etc Do not use flat or silver satin wire Crossover Cable 1 2 3 6 Straight Through Cable Twisted Pair 1 Twisted Pair 1 Twisted Pair 2 Twisted Pair 2 1 2 3 6 1 2 3 6 1 2 3 6 5 techsupport transition com Click the Transition Now link for a ...

Page 4: ...initialization process Contact Technical Support YES Contact Technical Support 6 J E CX TBT 02 24 hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 7 techsupport transition com Click the Transition Now link for a live Web chat Declaration of Conformity Name of Mfg Transition Networks 6475 City West Parkway Minneapolis MN 55344 U S A Model J E CX TBT 02 Series Media Converters P...

Page 5: ...partment of Communications Le présent appareil numérique n émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la Class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada European regulations Warning This is a Class A product In a domestic environment this product may cause radio interf...