background image

Operator’s Manual.

for the solar system owner

P   V     I   N   V   E   R   T   E   R   S

Summary of Contents for Powador 1501xi

Page 1: ...Operator s Manual for the solar system owner P V I N V E R T E R S...

Page 2: ...tions 2 3 Notes concerning installation and operation 3 3 1 Intended normal use 3 3 2 Factory warranty and liability 4 3 3 Service 3 4 Operation 4 4 1 Overview of operating elements and displays 5 4 2...

Page 3: ...ocument that the blueplanet xi series inverter indicated on the model label meets the fundamental requirements according to the following UL 1741 directives Directive concerning Electromagnetic Compat...

Page 4: ...ance for your photovoltaic installation from your utility company Some of the documents which are needed for these applications and acceptance are attached to these installation instructions 3 2 Facto...

Page 5: ...KACO Solar website describing how to avoid the effects of the fault If the concern is greater written explanation will be mailed to registered installers The solar system installer is responsible for...

Page 6: ...in the morning and terminates this process as it becomes dark On cloudy days or during the winter months the grid feeding process can be interrupted at certain times depending on the PV generator and...

Page 7: ...y change between the RS232 and RS485 interface by means of the adjustment key 2 If the RS485 interface is enabled you can set the address by means of the Display key 1 Using the Adjustment key 2 you m...

Page 8: ...ta can be transmitted to a computer e g notebook via an electrically isolated serial interface 3 and processed individually with any commercial spreadsheet program To connect the inverter to the PC yo...

Page 9: ...ngs in figure 4 7 Status Explanation Comment 0 Inverter has just switched on Only after the first start up in the morning 1 Waiting for start Grid parameters and generator voltage are checked 2 Waitin...

Page 10: ...ssage Explanation 1 Display shown during the starting up period in the morning after a malfunction or prior to night shutdown No grid feeding in this mode of operation The inverter waits until the vol...

Page 11: ...thin the specified range The unit detected a critical operating point and shut down to secure itself This error can be caused by a utility fault DC or AC power surges It will clear itself after a few...

Page 12: ...se Displayed in hours and minutes 12 Operating hours during the current calendar year January 1 to date 13 Operating hours since the time of inverter startup Table 4 3 Possible display messages Annual...

Page 13: ...you can observe the daily curve or read the current output or daily yield You will be able to recognize any problems in your installation very quickly The attractive display is suitable for use in hom...

Page 14: ...or not the device delivers power If power is delivered the display module is defective and the inverter has to be returned to KACO for repair If no power is delivered you should check that grid volta...

Page 15: ...s frequent changes between sun and clouds may cause a slight um due to high energy 8 Certain grid conditions may result in grid resonance between the input filter of the device and the grid which may...