RTPS
2-66
RTP 5.26 J396- CLOSER RE-HOME ENCODER TIMEOUT
J396 occurs when the S48 Closer Encoder Sensor does not change state
within a specified time after the M20 Closer Motor begins to move.
1. This may be caused by the closer cams being out of phase. A
symptom of this would be an increasing level of elements being
closed unevenly. To check this, remove the Front Closer Cover and
the Top Closer Cover by removing the M4 screws (3)
With this cover removed and the cams visible, perform GP 6.3.3 to
active M20. Watch the cams rotate.
Are the cams rotating in phase?
Yes
–
Go to step 2;
No
–
Perform ADJ 1.11 Closer Cam Phase Adjustment.
2. This jam may occur if more sheets were used in a book than the
currently loaded element size can accommodate. Consult Book
Quality Section 3.5.1 Book Size and correct the job if needed.
This clears the fault
Yes
- Return to normal operation;
No
- Go to Step 3
3. Ensure that there are no residual elements or foreign objects in the
Closer jaws.
Closer jaws are free of foreign materials
Yes
- Go to Step 6;
No
- Remove the object(s)
The jaws were able to be cleared.
Yes
- Go to Step 5;
No
- Go to Step 4
4. Do REP 6.4 to remove the M20 Closer Motor. Rotate the large drive
gear by hand to rotate the cams and release any objects stuck
between the jaws. Reinstall the Closer Motor and Closer Module.
Closer jaws are free of foreign materials
Yes
- Go to Step 5;
No
- Escalate to second level
5. Close all covers, and cycle the Element Feeder Door Interlock
This clears the fault
Yes
- Return to normal operation;
No
- Go to Step 6
6. Remove the M3 Screws (2) holding the Cable Access Cover. Check
that the Flat Mylar Closer Cable is plugged in and properly seated in
its housing as shown.
Cable is plugged in and properly seated
Yes
- Go to Step 7;
No
- Plug in the cable close all covers and cycle the Element Feeder
Door interlock.
This clears the fault
Yes
- Reinstall the Cable Cover and return to normal operation;
No
- Go to Step 8.
.
Summary of Contents for StreamWire
Page 9: ...GBC StreamWire 07 23 2020 Service Manual ix Notes...
Page 87: ...GBC StreamWire 07 23 2020 RTPS 2 72 Notes...
Page 89: ...Book Quality 07 23 2020 GBC StreamWire 3 2 This page intentionally left blank...
Page 428: ...GBC StreamWire 12 18 2018 Wiring Data 7 3 o System Wiring...
Page 429: ...Wiring Data 12 18 2018 GBC StreamWire 7 4 o Element Feeder Module...
Page 430: ...GBC StreamWire 12 18 2018 Wiring Data 7 5 o Element Transfer Module...
Page 431: ...Wiring Data 12 18 2018 GBC StreamWire 7 6 o Knife Module...
Page 432: ...GBC StreamWire 12 18 2018 Wiring Data 7 7 o Closer Module...
Page 433: ...Wiring Data 12 18 2018 GBC StreamWire 7 8 o Holder Module...
Page 434: ...GBC StreamWire 12 18 2018 Wiring Data 7 9 o Book Drawer...
Page 435: ...Wiring Data 12 18 2018 GBC StreamWire 7 10 o Paper Transport Module...
Page 436: ...GBC StreamWire 12 18 2018 Wiring Data 7 11 o Sheet Tappers Module...
Page 437: ...Wiring Data 12 18 2018 GBC StreamWire 7 12 o Deflector Module...
Page 438: ...GBC StreamWire 12 18 2018 Wiring Data 7 13 o Stacker Module...
Page 439: ...Wiring Data 12 18 2018 GBC StreamWire 7 14 o Alignment Module...
Page 440: ...GBC StreamWire 12 18 2018 Wiring Data 7 15 o Interlock AC and LCD Connections...
Page 442: ...Installation Instructions 03 26 2019 GBC StreamWire 8 2 This page intentionally left blank...