GBC StreamWire
07/23/2020
General Procedures and Information
6-41
The corresponding Nip rollers turn when the Motor is activated
Yes
- Return to the RTP that directed you here
No
- Identify the malfunctioning Motor(s) and go to Step 3.
3. Make sure the motor cable is connected securely at the Driver Board
and at the Main Control Board (PL 5.27). Do REP 1.5 to remove the
Rear Cover to gain access to the connector at the Control Board. Do
REP 1.1 to access the M1 and M2 Motor Driver Boards. To access
the M16-M18 Driver Boards, raise the Upper and Lower Transport
assemblies and remove the Underside cover (refer to REP 2.24).
All the connectors are securely connected.
Yes
- Go to Step 4
No
- Make the connection and resume operation
4. Inspect the timing belt for the motor. Confirm that the timing belt has
appropriate tension and that the belt is not damaged or frayed.
Timing belt is okay
Yes
- Go to Step 5
No
- Replace the faulty belt and resume operation
5. Check the tightness of the pulley set screw on the stepper motor
shaft. Also check the set screws/ coiled spring pins for all the pulleys
(PL 5.3) that are driven by the stepper motor in question. Skip this
step for M1 and M2, which do not have set screws.
All the set screws are secured tightly
Yes
- Go to Step 6
No
- Tighten the loose set screw and repeat Step 1
6. Check the DIP switch settings for the Motor. DIP Switches are located
on the Driver Board that corresponds with each motor. Refer to the
Table below for the correct DIP switch settings for each Motor.
DIP 1
DIP 2
DIP 3
DIP 4
DIP 5
M1
OFF
ON
OFF
ON
OFF
M2
OFF
ON
OFF
ON
OFF
M16
OFF
OFF
ON
ON
ON
M17
OFF
OFF
ON
OFF
ON
M18
OFF
OFF
ON
OFF
OFF
All the DIP switch setting are correct
Yes
- Go to Step 7
No
- Correct the DIP switch and repeat Step 1
7. Check if there is power to the Driver board. LED 1 on the Driver board
should be lit.
If LED 1 is lit, it means there is 24V DC power to the Driver board
from the Main Control board.
If LED 2 is lit, it means there is a fault with either the Driver board or
the stepper motor.
LED 1 is not Lit
- Go to Step 8
LED 1 is Lit
- Go to Step 9
8. Check that the cable(s) connecting the Driver Board 24 VDC signal to
the Main Control Board are intact. Refer to the motor cables table to
identify the appropriate cable part numbers,
The cables look okay
Yes
- Go to Step 10
No
- Replace the faulty cable and repeat Step 1
Summary of Contents for StreamWire
Page 9: ...GBC StreamWire 07 23 2020 Service Manual ix Notes...
Page 87: ...GBC StreamWire 07 23 2020 RTPS 2 72 Notes...
Page 89: ...Book Quality 07 23 2020 GBC StreamWire 3 2 This page intentionally left blank...
Page 428: ...GBC StreamWire 12 18 2018 Wiring Data 7 3 o System Wiring...
Page 429: ...Wiring Data 12 18 2018 GBC StreamWire 7 4 o Element Feeder Module...
Page 430: ...GBC StreamWire 12 18 2018 Wiring Data 7 5 o Element Transfer Module...
Page 431: ...Wiring Data 12 18 2018 GBC StreamWire 7 6 o Knife Module...
Page 432: ...GBC StreamWire 12 18 2018 Wiring Data 7 7 o Closer Module...
Page 433: ...Wiring Data 12 18 2018 GBC StreamWire 7 8 o Holder Module...
Page 434: ...GBC StreamWire 12 18 2018 Wiring Data 7 9 o Book Drawer...
Page 435: ...Wiring Data 12 18 2018 GBC StreamWire 7 10 o Paper Transport Module...
Page 436: ...GBC StreamWire 12 18 2018 Wiring Data 7 11 o Sheet Tappers Module...
Page 437: ...Wiring Data 12 18 2018 GBC StreamWire 7 12 o Deflector Module...
Page 438: ...GBC StreamWire 12 18 2018 Wiring Data 7 13 o Stacker Module...
Page 439: ...Wiring Data 12 18 2018 GBC StreamWire 7 14 o Alignment Module...
Page 440: ...GBC StreamWire 12 18 2018 Wiring Data 7 15 o Interlock AC and LCD Connections...
Page 442: ...Installation Instructions 03 26 2019 GBC StreamWire 8 2 This page intentionally left blank...