General Procedures and Information
07/23/2020
GBC StreamWire
6-46
GP 6.5.5
Check M9 and M10
Identify Motor M9 and M10:
•
Slide the element feeder drawer all the way out of the machine
•
M9 is located on the Element Feed Sprocket. M10 is located on
the Element Feed Belt drive, near the front of the drawer.
•
Insert a cheater into the element feeder door interlock switch
1. Do
to check the motors activate as
expected. M9 will rotate the Element Feed Sprocket. M10 will rotate
the Element Feeder Belt.
Motors turn as expected
Yes
- Return to the RTP that directed you here
No
- Go to Step 2.
2. Make sure the motor wire is connected securely at the Driver Board
and at the Main Control Board (PL 5.27). Do REP 1.5 to remove the
Rear Cover to gain access to the connector at the Control Board.
Refer to REP 3.8 to locate the M9 motor cable connections.
All the connectors are securely connected.
Yes
- Go to Step 3
No
- Make the connection and resume operation
3. Inspect the element feed belt. Manually advance the belt using the
attached knob to confirm that the belt is intact, and that nothing is
hindering the smooth advance of the belt.
Belt looks OK
Yes
- Go to Step 4
No
- Follow REP 3.6 to replace 7716993, Element Feeder Belt.
4. Check the tightness of the set screw of the pulley on the stepper
motor shaft.
All the set screws are secured tightly
Yes
- Go to Step 5
No
- Tighten the loose set screw and repeat Step 1
5. Check the DIP switch settings for the Driver Board. Refer to the table
below.
DIP 1
DIP 2
DIP 3
DIP 4
DIP 5
M9
ON
OFF
ON
OFF
ON
M10
ON
OFF
ON
OFF
OFF
DIP switch settings are correct
Yes
- Go to Step 6
No
- Correct the DIP switch and repeat Step 1
6. Check if there is power to the Driver board. LED 1 on the Driver board
should be lit.
If LED 1 is lit, it means there is 24V DC power to the Driver board
from the Main Control board.
If LED 2 is lit, it means there is a fault with either the Driver board or
the stepper motor.
Continue to Step 7
7. Check that the cable(s) connecting the Driver Board to the Main
Control Board are intact. Refer to the motor cables table to identify
the appropriate cable part numbers,
The cables look okay
Yes
- Go to Step 8
No
- Replace the faulty cable and resume normal operation
Summary of Contents for StreamWire
Page 9: ...GBC StreamWire 07 23 2020 Service Manual ix Notes...
Page 87: ...GBC StreamWire 07 23 2020 RTPS 2 72 Notes...
Page 89: ...Book Quality 07 23 2020 GBC StreamWire 3 2 This page intentionally left blank...
Page 428: ...GBC StreamWire 12 18 2018 Wiring Data 7 3 o System Wiring...
Page 429: ...Wiring Data 12 18 2018 GBC StreamWire 7 4 o Element Feeder Module...
Page 430: ...GBC StreamWire 12 18 2018 Wiring Data 7 5 o Element Transfer Module...
Page 431: ...Wiring Data 12 18 2018 GBC StreamWire 7 6 o Knife Module...
Page 432: ...GBC StreamWire 12 18 2018 Wiring Data 7 7 o Closer Module...
Page 433: ...Wiring Data 12 18 2018 GBC StreamWire 7 8 o Holder Module...
Page 434: ...GBC StreamWire 12 18 2018 Wiring Data 7 9 o Book Drawer...
Page 435: ...Wiring Data 12 18 2018 GBC StreamWire 7 10 o Paper Transport Module...
Page 436: ...GBC StreamWire 12 18 2018 Wiring Data 7 11 o Sheet Tappers Module...
Page 437: ...Wiring Data 12 18 2018 GBC StreamWire 7 12 o Deflector Module...
Page 438: ...GBC StreamWire 12 18 2018 Wiring Data 7 13 o Stacker Module...
Page 439: ...Wiring Data 12 18 2018 GBC StreamWire 7 14 o Alignment Module...
Page 440: ...GBC StreamWire 12 18 2018 Wiring Data 7 15 o Interlock AC and LCD Connections...
Page 442: ...Installation Instructions 03 26 2019 GBC StreamWire 8 2 This page intentionally left blank...