GBC StreamWire
07/23/2020
RTPS
2-13
2 POWER FAULTS
RTP 2.1 No AC Power
Use this RTP when there is no AC power to the eWire. The Operator
Panel does not illuminate and the eWire does not operate. Check if the
LEDs on the Main Control Board A and Main Control Board B are lit.
1. Ensure the Power is ON for the print engine, punch and eWire. The
Power switch is located at the rear side of the machine.
Main Power Switch is in the On (I) position
Y N
Place the Main Power Switch in the On (I) position.
2. Check that the Power Cord is attached to the AC Filter on the rear of
the machine.
Power Cord is attached to AC Filter.
Y N
Attach the Power Cord.
3. Check that the Power Cord is properly plugged into the wall.
Power Cord is plugged into the wall.
Y N
Plug in the Power Cord.
4. Disconnect the Power Cord from the power source and check the
power source voltage - 110 VAC (60 Hz) or 240 VAC (50 Hz) - at the
power receptacle.
AC power is present at correct value at the recepticle.
Y N
If there is no power at the outlet, ask the customer to call an
electrician to restore the AC power.
5. Reconnect the power cord to the eWire.
6. Do REP 1.5 to remove the Rear Cover.
7. Check that Ground Wire 7715525 (See Section 7, page 7-2) is
connected to the ground and to the AC Filter.
Ground Wire is connected.
Y N
Connect Ground Wire.
Go to step 8
8. Check that Cable 7716727 (See Section 7, page 7-2) is connected at
the AC Filter and the Power switch SW1 at the other end
Cable 7716727 (Black/White) is connected at both ends
Y N
Connect Cable 7716727
9. Check that Cable 7716729 (See Section 7, page 7-2) is connected to
the Power Switch at one end and at the input terminals of the 24 VDC
Power Supply at the other end.
Cable 7716729 (Black/White) is connected at both ends
Y N
Connect Cable 7716729
10. Check that Cable 7716726 (See Section 7, page 7-2) is connected to
the 24 VDC power supply and the Main Board A.
Cable 7716726 is connected.
Y N
Connect Cable 7716726
11. Check for input voltage - 110 VAC (60 Hz) or 240 VAC (50 Hz) - at
the AC Filter terminals.
There is AC power at the AC Filter.
Y N
Replace the AC power cord to the AC Filter.
12. Check for continuity at the AC Power Switch (PL 5.27).
There is continuity at the AC Power Switch.
Y N
Replace AC Power Switch 7704376 (REP 11.6)
13. Check for voltage - 110 VAC (60 Hz) or 240 VAC (50 Hz) – on Cable
7716728 (See Section 7, page 7-2) at the AC Filter.
There is AC power on Cable 7716728 at the AC Filter.
Y N
Replace AC FILTER (REP 11.5).
14. Check for voltage - 110 VAC (60 Hz) or 240 VAC (50 Hz) – on Cable
7716729 (See Section 7, page 7-2).
There is AC power on Cable 7716729.
Y N
Replace Cable 7716729
Summary of Contents for StreamWire
Page 9: ...GBC StreamWire 07 23 2020 Service Manual ix Notes...
Page 87: ...GBC StreamWire 07 23 2020 RTPS 2 72 Notes...
Page 89: ...Book Quality 07 23 2020 GBC StreamWire 3 2 This page intentionally left blank...
Page 428: ...GBC StreamWire 12 18 2018 Wiring Data 7 3 o System Wiring...
Page 429: ...Wiring Data 12 18 2018 GBC StreamWire 7 4 o Element Feeder Module...
Page 430: ...GBC StreamWire 12 18 2018 Wiring Data 7 5 o Element Transfer Module...
Page 431: ...Wiring Data 12 18 2018 GBC StreamWire 7 6 o Knife Module...
Page 432: ...GBC StreamWire 12 18 2018 Wiring Data 7 7 o Closer Module...
Page 433: ...Wiring Data 12 18 2018 GBC StreamWire 7 8 o Holder Module...
Page 434: ...GBC StreamWire 12 18 2018 Wiring Data 7 9 o Book Drawer...
Page 435: ...Wiring Data 12 18 2018 GBC StreamWire 7 10 o Paper Transport Module...
Page 436: ...GBC StreamWire 12 18 2018 Wiring Data 7 11 o Sheet Tappers Module...
Page 437: ...Wiring Data 12 18 2018 GBC StreamWire 7 12 o Deflector Module...
Page 438: ...GBC StreamWire 12 18 2018 Wiring Data 7 13 o Stacker Module...
Page 439: ...Wiring Data 12 18 2018 GBC StreamWire 7 14 o Alignment Module...
Page 440: ...GBC StreamWire 12 18 2018 Wiring Data 7 15 o Interlock AC and LCD Connections...
Page 442: ...Installation Instructions 03 26 2019 GBC StreamWire 8 2 This page intentionally left blank...