General Procedures and Information
07/23/2020
GBC StreamWire
6-16
GP 6.3.8
FILES Procedure
The Log procedure allows you to save information about machine settings
and past performance to a USB drive.
Enter Service Mode by following the procedure described in
Remove the Screws and remove the USB cover to access the USB port
on the rear of the eWire. Insert a USB drive to the port.
Backup/Restore Setting
Follow these steps to save the machine data to a USB so that they can
later be restored. These settings are set in the factory and updated
whenever an adjustment is performed on the eWire. Loss of these
settings will result in the eWire not functioning.
Press the down arrow until the return symbol is next to the words FILES.
Press OK/ENTER.
DATA
BACKUP
Scroll down and select BACKUP, the option to LOAD or SAVE will
appear. When backing up the old board, select SAVE, when loading a
backup from the USB onto a new board, select LOAD
LOAD
SAVE
If this back up is ever lost, the factory back up can be restored to the
machine, but any adjustment will have been lost. Take the USB from the
rear of the eWire and open it on a computer. Make a copy of
FACTORY_EEPROM_SN#####.BAK and rename this copy
C_EEPROM.BAK. Return the USB to the back of the machine and
perform the steps above to load the setting.
Retrieve Log Data
Press the down arrow until the return symbol is next to the words FILES.
Press OK/ENTER.
LOG
DATA
Select LOG to save the current log file to a USB storage device located
on the back panel. The file name will be LOG0001.txt, and increment
each time the log is saved.
SAVE TO USB
PREVIOUS MENU
Press Enter to save the current Log File to your USB storage device. You
will receive a message showing the log has been saved and the name of
the Log File. Press OK/ENTER to return to the service menu.
Retrieve Setting Data
The settings can be retrieved in a readable text file.
Press the down arrow until the return symbol is next to the words FILES.
Press OK/ENTER.
LOG
DATA
Select DATA to save machine settings to USB. It is recommended to save
settings each time a change is made. Select SAVE TO USB and press
ENTER to save current machine settings
Summary of Contents for StreamWire
Page 9: ...GBC StreamWire 07 23 2020 Service Manual ix Notes...
Page 87: ...GBC StreamWire 07 23 2020 RTPS 2 72 Notes...
Page 89: ...Book Quality 07 23 2020 GBC StreamWire 3 2 This page intentionally left blank...
Page 428: ...GBC StreamWire 12 18 2018 Wiring Data 7 3 o System Wiring...
Page 429: ...Wiring Data 12 18 2018 GBC StreamWire 7 4 o Element Feeder Module...
Page 430: ...GBC StreamWire 12 18 2018 Wiring Data 7 5 o Element Transfer Module...
Page 431: ...Wiring Data 12 18 2018 GBC StreamWire 7 6 o Knife Module...
Page 432: ...GBC StreamWire 12 18 2018 Wiring Data 7 7 o Closer Module...
Page 433: ...Wiring Data 12 18 2018 GBC StreamWire 7 8 o Holder Module...
Page 434: ...GBC StreamWire 12 18 2018 Wiring Data 7 9 o Book Drawer...
Page 435: ...Wiring Data 12 18 2018 GBC StreamWire 7 10 o Paper Transport Module...
Page 436: ...GBC StreamWire 12 18 2018 Wiring Data 7 11 o Sheet Tappers Module...
Page 437: ...Wiring Data 12 18 2018 GBC StreamWire 7 12 o Deflector Module...
Page 438: ...GBC StreamWire 12 18 2018 Wiring Data 7 13 o Stacker Module...
Page 439: ...Wiring Data 12 18 2018 GBC StreamWire 7 14 o Alignment Module...
Page 440: ...GBC StreamWire 12 18 2018 Wiring Data 7 15 o Interlock AC and LCD Connections...
Page 442: ...Installation Instructions 03 26 2019 GBC StreamWire 8 2 This page intentionally left blank...