GP 6.3.21
CLSR OPEN DELAY
The Closer Full Open Delay setting adjusts how wide the closer jaws
open when homing while binding an F size element. This setting does not
affect the closer homing behavior when a non-F size spool is installed in
the machine.
NOTE: This setting is only visible when an F size spool is installed in
the eWire.
Using the procedure described in
, enter Service mode.
Use the up and down arrows to scroll down to the CLSR OPEN DELAY
CLSR OPEN DELAY
*
The below screen will appear
CLSR OPEN DELAY
*
0
0 is the default setting. Closer Full Open Delay can be adjusted on a
range of 0 to +500. When the desired value has been selected, press
OK/ENTER to return to the service menu.
Select EXIT and press OK/ENTER to return to the top level menu
GP 6.3.22
Factory Only
This contains settings that are set by the factory and should not be
modified unless directed to during an escalation.
To access these settings, Enter Service Mode by following the procedure
described in
Press the down arrow until the return symbol is next to the words
FACTORY ONLY. Press OK/ENTER.
FACTORY ONLY
The following settings are available through this menu:
GP 6.4 Check Sensors
Use the information in this section to locate the appropriate sensor(s) on
the eWire. Once you have located the sensor, follow
the function of the sensor. If the sensor does not operate as expected,
follow the troubleshooting steps located in this section to fix the faulty
sensor.
GP 6.4.1
Check S1-S5, S16, S43, S45
Use the information in this section to locate the appropriate sensor(s) on
the eWire. Once you have located the sensor, follow
the function of the sensor. If the sensor does not operate as expected,
follow the troubleshooting steps located in this section to fix the faulty
sensor.
Locate sensors S1, S4, S5, and S16:
•
Raise the Top Cover.
•
The sensor windows are located on the Upper Bypass, oriented
toward the paper path.
•
Sensors S1, S4, S5, and S16 can be blocked manually by using
a piece of paper or other solid object.
Sensors S1, S4, S5 and S16 are on the Upper Bypass Panel (PL
5.2).
Summary of Contents for StreamWire
Page 9: ...GBC StreamWire 07 23 2020 Service Manual ix Notes...
Page 87: ...GBC StreamWire 07 23 2020 RTPS 2 72 Notes...
Page 89: ...Book Quality 07 23 2020 GBC StreamWire 3 2 This page intentionally left blank...
Page 428: ...GBC StreamWire 12 18 2018 Wiring Data 7 3 o System Wiring...
Page 429: ...Wiring Data 12 18 2018 GBC StreamWire 7 4 o Element Feeder Module...
Page 430: ...GBC StreamWire 12 18 2018 Wiring Data 7 5 o Element Transfer Module...
Page 431: ...Wiring Data 12 18 2018 GBC StreamWire 7 6 o Knife Module...
Page 432: ...GBC StreamWire 12 18 2018 Wiring Data 7 7 o Closer Module...
Page 433: ...Wiring Data 12 18 2018 GBC StreamWire 7 8 o Holder Module...
Page 434: ...GBC StreamWire 12 18 2018 Wiring Data 7 9 o Book Drawer...
Page 435: ...Wiring Data 12 18 2018 GBC StreamWire 7 10 o Paper Transport Module...
Page 436: ...GBC StreamWire 12 18 2018 Wiring Data 7 11 o Sheet Tappers Module...
Page 437: ...Wiring Data 12 18 2018 GBC StreamWire 7 12 o Deflector Module...
Page 438: ...GBC StreamWire 12 18 2018 Wiring Data 7 13 o Stacker Module...
Page 439: ...Wiring Data 12 18 2018 GBC StreamWire 7 14 o Alignment Module...
Page 440: ...GBC StreamWire 12 18 2018 Wiring Data 7 15 o Interlock AC and LCD Connections...
Page 442: ...Installation Instructions 03 26 2019 GBC StreamWire 8 2 This page intentionally left blank...