CHAPTER 12 POSITIONING DATA
12-8
Settings
12
12.2.1.3
Stand still timer (stop time)
After the motor has reached a specified position of the positioning data, when the set time of the stand
still timer has passed, the in position [INP] signal is output outside. (It is impossible to set the stand
still timer on immediate value data.)
This timer can be set from 0.00 to 655.35 s in increments of 0.01 s.
By changing the setting of the PA2_42 decimal point position of stand still timer, it is also allowed to
set from 0.000 to 65.535 s.
12.2.1.4
Acceleration time and deceleration time
Set an acceleration/deceleration time of the servo motor.
Setting value of the acceleration/deceleration time is a time setting before reaching 0 to 2000 r/min.
However, if the setting is 0.0 (default value), as shown in the table below, the motor follows the
acceleration/deceleration time is set by parameters by turning ON/OFF ACC0.
For details of acceleration time and deceleration time, refer to “PA1_36 to 40 Acceleration time and
deceleration time settings” in CHAPTER 4 on page 4-21.
ACC0 (14)
Acceleration time
Deceleration time
OFF PA1_37
PA1_38
ON PA1_39
PA1_40
Rotation
speed
Ready
Stand still timer of positioning data
Time
ON
ON
OFF
Start
positioning
AD3-AD0
5
9
In position
(lNP)
ON
OFF
ON
M code (output
at startup)
Stand still timer
(stop time)
FF
FF
20
・
Positioning data are regarded as being executed while the timer is measured.
・
The default value of the M code is "FF" (changeable into "00" by PA2_43).
Position data (stop position)
Speed data (rotation speed)
No. 5
(M code : 20)
Summary of Contents for ALPHA5 Smart
Page 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Page 2: ......
Page 4: ...ii...
Page 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Page 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Page 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Page 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Page 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Page 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Page 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Page 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Page 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Page 635: ......