CHAPTER 2 WIRING
2-8
Configuration
2
2) Connecting to peripheral devices (Servo amplifier frames 2, 3 and 4)
For the motors with the Cannon connector, connect cables as shown below.
mo
le
x
MCCB/ELCB
Servo amplifier
Servomotor
Encoder cable
AC reactor
Power filter
Motor power cable
(Should be fabricated by the customer.)
Electromagnetic
contactor
External regenerative resistor
(Disconnect the jumper wire and
connect across pins 2 and 3.)
RS-485
communications
(L1, L2, L3)
Grounding
terminal (M4)
Sequence I/O
cable
Connect pushbuttons,
various sensors, and
pulse input/output
signals.
TB1
CN3A
CN3B
CN1
CN2
TB2 (Provided with body)
Servo Operator (optional)
Using this, parameter
copying and editing can be
performed.
TB3
Surge
absorber
Summary of Contents for ALPHA5 Smart
Page 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Page 2: ......
Page 4: ...ii...
Page 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Page 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Page 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Page 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Page 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Page 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Page 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Page 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Page 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Page 635: ......