CHAPTER 13 RS-485 COMMUNICATIONS
Modbus RTU Communications
13-37
13
(3) Write “0” (OFF) to [START]. (This is to generate a rising edge in the next start.)
Query:
01 10 0000 0002 04 00000000 F3AF (13 bytes)
Response: 01 10 0000 0002 41C8 (8 bytes)
(4) Write immediate value data setting 2, which is for the next operation, as immediate value data.
The immediate value data operation follows the immediate value data read at the start (rising
edge of [START]). After operation is started, you can write the following setting as immediate
value data.
Setting 2: Immediate value position = -100000 units.
Immediate value speed = 200.00 r/min
Query:
01 10 5101 0004 08 FFFE7960 00004E20 667A (17 bytes)
Response: 01 10 5101 0004 80F6 (8 bytes)
(5) Read [INP] and check that immediate value data operation 1 is finished.
If [INP] is turned off, immediate value data operation 1 is in progress. (5) is repeated until [INP]
is turned on.
Query:
01 03 0100 0002 C5F7 (8 bytes)
Response: 01 03 04 0000 000
0
FA33 (9 bytes)
If “
1
”, [INP] is turned on.
Because immediate value data operation 1 is finished, the
process proceeds to step (6).
(6) Write “1” (ON) at [START] to start positioning operation. (Immediate value data operation 2
based on immediate value data setting 2 starts.)
Query:
01 10 0000 0002 04 00000001 326F (13 bytes)
Response: 01 10 0000 0002 41C8 (8 bytes)
(7) Write “0” (OFF) at [START]. (This is to generate a rising edge at the next start.)
Query:
01 10 0000 0002 04 00000000 F3AF (13 bytes)
Response: 01 10 0000 0002 41C8 (8 bytes)
(8) Read [INP] and check that immediate value data operation 2 is finished.
If [INP] is OFF, immediate value data operation 1 is in progress. Repeat step (8) until [INP] is
turned on.
Query:
01 03 0100 0002 C5F7 (8 bytes)
Response: 01 03 04 0000 000
0
FA33 (9 bytes)
If “
1
”, [INP] is turned on.
Immediate value data operation 1 is finished.
Summary of Contents for ALPHA5 Smart
Page 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Page 2: ......
Page 4: ...ii...
Page 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Page 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Page 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Page 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Page 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Page 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Page 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Page 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Page 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Page 635: ......