CHAPTER 2 WIRING
2-84
Description of I/O Signals
2
Parameter
setting
Enter the corresponding value (“81”) to the output terminal function setting parameter. The relevant
signal reference values are shown below.
Allocated signal
No.
Immediate value change
23
Immediate value change completion
81
Command positioning completion: Sequence output signal (Reference value 82)
The signal is turned on after the command value inside the servo amplifier is completed.
Function
The signal undergoes ON-to-OFF transition at the start of operation and OFF-to-ON transition
upon elimination of the internal command during manual feed, positioning, homing or interrupt
positioning. However, even if the command is eliminated, in the case of the automatic-operation
continuation stand still timer counting cycle for example, the OFF state continues during operation.
When continuation of operation is disabled due to alarm detection, emergency stop detection or
OT detection, this signal is immediately turned on.
ON
Command positioning
completion
In-position
Speed
Time
ON
ON
Start positioning
OFF
OFF
Command
Motor speed
Summary of Contents for ALPHA5 Smart
Page 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Page 2: ......
Page 4: ...ii...
Page 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Page 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Page 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Page 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Page 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Page 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Page 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Page 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Page 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Page 635: ......