CHAPTER 13 RS-485 COMMUNICATIONS
13-46
PC Loader Communications
13
Standard connection diagram
Frame 1
CN1
OUT1 15
OUT2 16
OUT3 17
3
Commercial power supply:
In case of single-phase 200 V input, connect
to the L1 and L2 terminals.
2
External braking
resistor
*FFB 12
*FFZ 24
*FFA 10
FZ 25
M5 26
FFA 9
FFB 11
FFZ 23
7 CA
8 *CA
21 *CB
20 CB
19 PPI
18 TREF
13 M5
1
2
3
1 COMIN
2 CONT1
5 CONT4
3 CONT2
6 CONT5
COMOUT 14
4 CONT3
1
2
3
M5 4
M5 3
MON2 2
MON1 1
CN4
BAT-(M5) 1
BAT+ 2
CN5
1
4
22 VREF
13 M5
Connect the external braking resistor
across RB1 and RB2. (Remove the
jumper wire from RB2 and RB3.)
RB2
RB1
P(+)
N(-)
TB2
L1
L2
L3
TB1
U
V
W
TB3
PN junction
※3
※3
M
PG
1 U
2 V
3 W
4
1 Br
2 Br
7 P5
8 M5
5 SIG+
4 SIG-
1 BAT+
2 BAT-
3 FG
CN2
P5 1
M5 2
+SIG 5
-SIG 6
BAT+ 3
BAT- 4
24 VDC
S
G
3
6
5
4
1
8
2
7
3
6
5
4
1
8
2
7
M5
M5
P5
N.C.
CN3A(IN)
CN3B(OUT)
Servomotor
Servo amplifier
RYH-VV type
(Frame 2)
Connect the external regenerative resistor
across RB1 and RB2. (Remove the
jumper wire from RB2 and RB3.)
External regenerative
Resistor
Summary of Contents for ALPHA5 Smart
Page 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Page 2: ......
Page 4: ...ii...
Page 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Page 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Page 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Page 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Page 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Page 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Page 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Page 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Page 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Page 635: ......