CHAPTER 4 PARAMETER
4-78
Automatic Operation Setting Parameter
4
Setting value: 0 (Internal command completion.)
After the command in-position of each motion, next operation will be carried out continuously (in
continuous operation) as shown in the chart below.
The current feedback position while continuous operation is carried out may not reach the target
position due to delay of following behavior.
To approach the target position, adjust the tuning setting and increase the response.
Internal command
completion
Internal feedback
completion
Speed
These timings may not
allow reaching to the
target position.
ON
Start positioning
OFF
OFF
ON
Target
position
Position
ON
ON
ON
Time
In-position[INP]
OFF
ON
ON
Summary of Contents for ALPHA5 Smart
Page 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Page 2: ......
Page 4: ...ii...
Page 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Page 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Page 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Page 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Page 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Page 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Page 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Page 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Page 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Page 635: ......