CHAPTER 4 PARAMETER
Automatic Operation Setting Parameter
4-79
4
Setting value: 1 (Internal feedback completion.)
The operation will shift to the next motion continuously after each motion enters in-position conditions
(*) as shown in the chart below.
The current feedback position while continuous operation is carried out will start the following motion
to the target position after positioning is complete normally.
* Conditions for in-position is all of the following (a), (b) and (c).
(a) Internal command completion (b) The position deviation is within the deviation zero range
(PA1_32) (c) The speed is within the zero speed range (PA1_30)
Moreover, the in-position [INP] signal is not output during continuous operation.
Command
Motor
speed
Internal command
completion
Internal feedback
completion
Speed
Time
ON
Start positioning
OFF
ON
Target
position
Position
ON
ON
ON
Time
OFF
ON
ON
ON
ON
In-position [INP]
OFF
ON
Summary of Contents for ALPHA5 Smart
Page 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Page 2: ......
Page 4: ...ii...
Page 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Page 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Page 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Page 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Page 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Page 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Page 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Page 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Page 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Page 635: ......