CHAPTER 7 MAINTENANCE AND INSPECTION
Approximate Replacement Timing
7-19
7
7.6 Approximate Replacement Timing
The approximate replacement timings of parts for the following operating conditions are shown below.
However, note that the timing varies according to the operation method, environmental conditions and
so on. For the replacement method, contact us.
[Operating conditions]
Ambient temperature:
Annual average 30°C
Load factor:
Within 80%
Operation rate:
Within 20 hours/day
Servomotor
Part name
Standard service life
Method
Bearing
20,000 to 30,000 hours
Oil seal
5,000 hours
Send the product back
to us for repair.
Servo
amplifier
Part name
Standard service life
Method
Capacitors of main circuit
73,000 hours
Aluminum electrolytic capacitors
of printed circuit board
73,000 hours
Cooling fan
73,000 hours
Fuse 73,000
hours
Send the product back
to us for repair.
Battery for absolute system
35,000 hours *1
Replace with a new part.
*1 Cumulative operation hours without tuning the power on
Summary of Contents for ALPHA5 Smart
Page 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Page 2: ......
Page 4: ...ii...
Page 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Page 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Page 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Page 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Page 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Page 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Page 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Page 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Page 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Page 635: ......