CHAPTER 4 PARAMETER
Extended Function Setting Parameter
4-83
4
The enabled torque limit is described below.
(1) In case of position control and speed control (If PA2_57 is 0)
CONT signal *
State of each limit
Enabled torque limit
Torque
limit 1
Torque
limit 0
TL: TREF (analog torque limit)
CCW: Powering,
CW: Regeneration
CW: Powering,
CCW: Regeneration
OFF
OFF
No condition judgment
Forward rotation
torque limit
Reverse rotation
torque limit
TL
≥
Forward/Reverse rotation torque limit
Forward rotation
torque limit
Reverse rotation
torque limit
OFF ON
TL < Forward/reverse rotation torque limit
TL
TL
Second torque limit
≥
Forward/Reverse rotation
torque limit
Forward rotation
torque limit
Reverse rotation
torque limit
ON OFF
Second torque limit < Forward/Reverse torque
limit
Second torque
limit
Second torque
limit
TL
≥
Second torque limit
Second torque
limit
Second torque
limit
ON ON
TL < Second torque limit
TL
TL
Add a positive voltage to TL. The negative voltage is limited to zero.
A negative setting is limited to zero.
If PA2_57 is 1, the torque limit is always the TL value.
(2) In case of torque control
The forward rotation torque limit and reverse rotation torque limit are followed.
(3) Torque limit for controlled stop action (under position or speed control) (If PA2_57 is 0)
CONT signal *
State of each limit
Enabled torque limit
Torque
limit 1
Torque
limit 0
TL: TREF (analog torque limit)
CW deceleration
stop
CCW deceleration
stop
Forward rotation torque limit
≥
Third
torque limit
Third torque limit
Third torque limit
OFF OFF
Forward/Reverse rotation torque limit <
Third torque limit
Forward rotation torque
limit
Reverse rotation torque
limit
TL, forward/reverse torque limit
≥
Third
torque limit
Third torque limit
Third torque limit
OFF ON
TL, forward/reverse torque limit < Third
torque limit
TL or forward rotation
torque limit, whichever
is less
TL or reverse rotation
torque limit, whichever
is less
Second torque limit, forward/reverse
rotation torque limit
≥
Third torque limit
Third torque limit
Third torque limit
ON OFF
Second torque limit, forward/reverse
rotation torque limit < Third torque limit
Second torque limit or
forward rotation torque,
whichever is less
Second torque limit or
reverse rotation torque,
whichever is less
TL, second torque limit
≥
Third torque
limit
Third torque limit
Third torque limit
ON ON
TL, second torque limit < Third torque
limit
TL or second torque
limit, whichever is less
TL or second torque
limit, whichever is less
If PA2_57 is 1, the torque limit is always the TL value.
Summary of Contents for ALPHA5 Smart
Page 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Page 2: ......
Page 4: ...ii...
Page 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Page 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Page 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Page 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Page 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Page 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Page 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Page 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Page 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Page 635: ......