CHAPTER 13 RS-485 COMMUNICATIONS
13-54
PC Loader Communications
13
Parameter
read
7
0
See the table below.
Quantity (01h to 15h)
No.(01h to 99h)
00h
(Designated No. x 6) + 2
DATA
(n)
50h
CMND
* Designate addresses (L) and (M) in a BCD.
Example: 49
→
49h, 50
→
50h
Parameter of designated No. (6 bytes)
(8th digit)
Data status
0: Normal. 1: Memory error
Data sign
0: +, 1: -
7
0
(7th digit)
(6th digit)
(5th digit)
(4th digit)
(3rd digit)
(2nd digit)
(1st digit)
(Decimal point position)
0
0
* The data is a 10-digit BCD.
7
0
See the table on the left.
00h
(Designated No. x 6) + 2
STR1
STR2
Parameter of
designated No.
No.(01h to 99h)
Quantity (01h to 4h)
Parameter of
designated No. + 1
Parameter of designated
No. + Designated
quantity - 1
Memory type
Parameter
21h
PA1_
22h
PA2_
23h
PA3_
(10th digit)
(9th digit)
00h
00h
Sent from host controller
Memory type
Address (L)
Address (M)
Address (H)
Number of readed
out bytes (L)
Number of readed
out bytes (H)
Sent from servo amplifier
Memory type
Address (L)
Address (M)
Address (H)
Number of readed out
bytes (L)
Number of readed out
bytes (H)
Status data
×
×
Summary of Contents for ALPHA5 Smart
Page 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Page 2: ......
Page 4: ...ii...
Page 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Page 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Page 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Page 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Page 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Page 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Page 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Page 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Page 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Page 635: ......