22. Multi-turn Data Over Flow
[Display]
[Description of detected alarm]
[Cause and remedy]
Cause Remedy
Excessive servomotor revolutions
Check the servomotor revolutions.
Use the PC Loader or take similar measures to
check the current position.
23. Initial Error
[Display]
[Description of detected alarm]
[Cause and remedy]
Cause Remedy
The encoder is damaged.
Replace the servomotor.
The power is turned on while the
servomotor rotates due to an external force
(at 250 r/min or over).
Stop the servomotor and turn the power off then
on again. If restoration is not obtained, replace
the servomotor.
Rotation of the output shaft of the servomotor exceeds the range
between -32766 and 32765.
The initial position inside the encoder is not established.
AF
iE
Summary of Contents for ALPHA5 Smart
Page 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Page 2: ......
Page 4: ...ii...
Page 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Page 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Page 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Page 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Page 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Page 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Page 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Page 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Page 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Page 635: ......