CHAPTER 4 PARAMETER
Automatic Operation Setting Parameter
4-55
4
(3) At-start reverse rotation homing profile1 (equivalent to homing profile 3 of FALDIC-
α
Series)
After homing is started, a travel occurs in the direction opposite to the starting direction for homing
by the specified reverse traveling unit amount for homing while the reference signal for homing
(deceleration starting signal) is searched for.
This profiles used if the machine stopping position is larger than the reference signal for homing
(deceleration starting signal) or reference signal for shift operation.
[Parameter setting example]
PA1_
No. Name
Setting
Default
value
Change
01
Control mode selection
6: Extension mode
0
Power
PA2_
No. Name
Setting
Default
value
Change
06
Homing speed
500.00 [r/min]
500.00
Always
07
Creep speed for homing
50.00 [r/min]
50.00
Always
08
Starting direction for homing
0: Forward rotation
0
Power
09
Reverse traveling unit amount for
homing
20000 [units]
0
Always
10
Homing direction after reference
signal detection
0: Forward rotation
0
Power
11
Reference signal for shift
operation
1: Encoder Z-phase
1
Power
12
Reference signal for homing
(Deceleration starting signal)
0: Home position LS
0
Power
13
Home position LS signal edge
selection
0: Rising edge
0
Power
14
Home position shift unit amount
1000 [units]
1000
Always
15
Deceleration operation for creep
speed
0: Reverse rotation is
disabled
0
Power
16
Home position after homing
completion
0 [units]
0
Always
17
Home position detection range
0: Always ON after homing
completion
0 Always
18
Deceleration time at OT during
homing
100.0 [ms]
100.0
Always
24
Selection of operation at OT
during homing
0: Reverse rotation
0 Power
Because rotation reverses in the direction opposite to the OT direction upon OT detection to
detect the reference signal for homing (deceleration starting signal) and reference signal for shift
operation, secure homing is realized. The reverse rotation after OT detection follows (2) OT
reference homing profile.
Summary of Contents for ALPHA5 Smart
Page 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Page 2: ......
Page 4: ...ii...
Page 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Page 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Page 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Page 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Page 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Page 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Page 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Page 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Page 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Page 635: ......