CHAPTER 7 MAINTENANCE AND INSPECTION
Troubleshooting Method
7-11
7
14. Internal Regenerative Resistor Overheat
[Display]
[Description of detected alarm]
[Cause and remedy]
Cause Remedy
Excessive source voltage
(immediately after power-on)
Check if the source voltage is within specification limits.
Insert a reactor if there is a power factor improvement capacitor.
Increase the deceleration time.
Decrease the servomotor rotation speed.
Increase the cycle time and decrease the operation frequency.
Due to vertical transfer or
winding purpose, etc. the
regenerative power cannot be
consumed.
Connect an external regenerative resistor.
Install a counterweight.
The regenerative resistor is not
connected.
Connect correctly. Set PA2_65 at 0 or 2.
Note: The internal regenerative resistor is possibly to get hot, so do not touch it.
15. External Regenerative Resistor Overheat
[Display]
[Description of detected alarm]
[Cause and remedy]
Cause Remedy
Excessive source voltage
(immediately after power-on)
Check if the source voltage is within the specification limits.
Increase the deceleration time.
Decrease the servomotor rotation speed.
Increase the cycle time and decrease the operation frequency.
Due to vertical transfer or
winding purpose, etc. the
regenerative, power cannot be
consumed.
Connect an external regenerative resistor.
Install a counterweight.
Wrong wiring of external
regenerative resistor overheat
signal
Connect correctly.
The power consumption of the regenerative resistor built in the
servo amplifier exceeds the upper limit. (Detection is made at
the internal electronic thermal relay of the servo amplifier.)
The external regenerative resistor overheat signal (normally closed
contact signal) has worked (was open).
rH1
rH2
Summary of Contents for ALPHA5 Smart
Page 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Page 2: ......
Page 4: ...ii...
Page 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Page 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Page 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Page 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Page 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Page 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Page 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Page 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Page 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Page 635: ......