CHAPTER 4 PARAMETER
4-88
Extended Function Setting Parameter
4
PA2_72 Station number
No. Name
Setting
range
Default value
Change
72 Station number
Station No.: 1 to 31
1
Power
Specify the station number of the amplifier.
RS-485 type: Specify the station number of each station.
PA2_73 Communication baud rate (RS-485)
No. Name
Setting
range
Default value
Change
73
Communication baud rate
(RS-485)
0: 38400 [bps] 1: 19200 [bps]
2: 9600 [bps] 3: 115200 [bps]
0 Power
Specify the communication baud rate of the system combined over RS-485.
PA2_74 Parameter write protection
No. Name
Setting
range
Default
value
Change
74 Parameter write protection 0: Write enable 1: Write protect
0
Always
Specify parameter write protection.
Enter "1" to prohibit parameter editing. Only this parameter can be changed.
PA2_75 Positioning data write protection
No. Name
Setting
range
Default
value
Change
75
Positioning data write
protection
0: Write enable 1: Write protect
0
Always
Specify positioning data write protection.
Enter "1" to prohibit positioning data editing.
Summary of Contents for ALPHA5 Smart
Page 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Page 2: ......
Page 4: ...ii...
Page 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Page 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Page 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Page 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Page 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Page 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Page 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Page 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Page 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Page 635: ......