CHAPTER 3 OPERATION
Operation
3-11
3
3.4.4 Torque Control
The shaft output torque is controlled under the torque control according to torque command voltage
input [TREF] of the servo amplifier or a parameter setting.
If parameter PA1_01 is set at "2," the torque control mode starts after the RDY signal is turned on.
The torque is output while the manual forward command [FWD] or manual reverse command [REV]
signal is turned on, while the torque is reduced to zero after the signal is turned off.
Use parameter PA1_60 to specify the torque setting filter.
The maximum motor rotation speed can be controlled.
No. Name
Setting
Default
value
Change
PA2_56
Speed limit selection
at torque control
0: Parameter (PA1_26)
1: As per multi-step speed selection incl.
VREF terminal voltage
0 Power
The speeds corresponding to multi-step speed selection (X3, X2 and X1) are given with
PA1_41 to PA1_47, or [VREF] terminal.
Because the speed control is not performed, the actual speed limit level is different.
[RDY]
ON
ON
Torque
OFF
Torque setting filter
Manual forward
command [FWD]
TREF voltage
Applied
Summary of Contents for ALPHA5 Smart
Page 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Page 2: ......
Page 4: ...ii...
Page 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Page 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Page 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Page 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Page 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Page 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Page 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Page 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Page 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Page 635: ......