CHAPTER 14 PC LOADER
14-6
Communications Setting
14
14.3 Communications Setting
Two methods are available to connect the servo amplifier to a PC.
The communications setting detail varies depending on the connection method. See the following
description and set the communications appropriately.
1) When using the RS-232C/485 converter (NW0H-CNV)
Wiring
outline
Setting
method
(1) Select "Comm. Setup" from
Wizard Menu.
(2) Select "It communicates directly with the
amplifier(COM)." in the Connection method
item, and then click the OK button.
Notes
Set the same value between PA2_73 (communications baud rate) on the amplifier side and the
communications baud rate as a communications condition.
No.
Parameter name
Setting range
Default value Change
PA2_73 Communications
baud rate
0
・・・
38400 [bps]
、
1
・・・
19200 [bps]
2
・・・
9600 [bps]
、
3
・・・
115200 [bps]
0 Power
PC
Loader
RS-232C/485 converter
(NW0H-CNV)
CAT5 cable
(commercial item)
USB/serial cable
(commercial item)
Summary of Contents for ALPHA5 Smart
Page 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Page 2: ......
Page 4: ...ii...
Page 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Page 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Page 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Page 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Page 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Page 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Page 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Page 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Page 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Page 635: ......