CHAPTER 3 OPERATION
Operation
3-15
3
3.4.7 Homing
When in-position [INP] is turned on, activation of the homing command [ORG] starts a homing motion.
Enter parameters PA2_06 through 18 and 24 to configure the homing pattern.
For details of the homing pattern settings, refer to “CHAPTER 4 PARAMETER.”
The homing motion can be interrupted with forced stop [EMG].
The in-position [INP] signal shown in the figure assumes the level output mode.
If positioning completion single shot output is selected at the parameter PA1_33, check for
stoppage with an external circuit before executing operation.
Speed
Time
[RDY]
ON
[INP]
ON
[ORG]
OFF
ON
OFF
ON
[LS] OFF
ON
Encoder Z-phase
ON
OFF
OFF
Homing completion
OFF
ON
Homing speed
Homing
creeping speed
Shift amount for
homing
OFF
OFF
Home position
LS detection
OFF ON
OFF
Summary of Contents for ALPHA5 Smart
Page 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Page 2: ......
Page 4: ...ii...
Page 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Page 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Page 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Page 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Page 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Page 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Page 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Page 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Page 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Page 635: ......