CHAPTER 13 RS-485 COMMUNICATIONS
PC Loader Communications
13-45
13
13.2.11 Wiring (CN3)
Connect to the host controller with marketed LAN cable.
Connect between the host (master) and servo amplifier (slave) so that the output of the host controller
becomes the input of the servo amplifier.
Connect between a servo amplifier (slave) and another servo amplifier (slave) with a straight cable.
The connector is RJ-45 (8 pins). No termination is necessary.
Up to 31 servo amplifiers can be connected.
Pin layout of connector
IN port (CN3A)
OUT port(CN3B)
8 P5
7 M5(0V)
6 *TXD
5 RXD
4 *RXD
3 TXD
2 M5(0V)
1 P5
(Upper side)
(Lower side)
8
N.C.
7
M5(0V)
6
*TXD
5
RXD
4
*RXD
3
TXD
2
M5(0V)
1
N.C.
Host
controller
No terminal
resistor is
needed.
Summary of Contents for ALPHA5 Smart
Page 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Page 2: ......
Page 4: ...ii...
Page 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Page 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Page 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Page 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Page 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Page 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Page 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Page 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Page 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Page 635: ......