CHAPTER 4 PARAMETER
Automatic Operation Setting Parameter
4-47
4
PA2_15 Deceleration operation for creep speed
No. Name
Setting
range
Default
value
Change
15
Deceleration operation for
creep speed
0: Reverse rotation is
disabled
1: Reverse rotation is
enabled
0 Power
Not a compulsory item
Specify 1 (reverse rotation is enabled) to return upon detection of the reference signal for shift
operation during movement at the homing speed in the homing direction after reference signal
detection temporarily to the point ahead of the reference signal for shift operation and move at the
creep speed for homing again in the homing direction after reference signal detection to the position
(home position) the home position shift unit amount away from the reference signal for shift operation.
Accurate homing can be executed only with the reference signal for shift operation without a reference
signal for homing (deceleration starting signal).
PA2_16 Home position after homing completion
No. Name
Setting
range
Default
value
Change
16
Home position after homing
completion
-2000000000 to 2000000000
[units]
0 Always
Not a compulsory item
Specify the coordinate position of the homing completion point.
After a homing is normally finished, the current position is
replaced with the reference value of this parameter.
Specify if the homing motion completion point is other than zero.
(1) Homing speed
(homing direction after reference signal
detection)
(2) Homing creep speed
(reverse)
(3) Homing creep speed (homing
direction after reference signal detection)
Reference signal for shift
operation
Reference signal for shift
operation
Reference signal for shift
operation
Speed
Time
OFF
ON
(3) Homing creep speed
+
-
(1)Homing speed
Reference signal for
homing
(2) Homing creep speed
ON
ON
OFF
OFF
OFF
Home position shift unit amount
Home position
Reference signal for
shift operation
Home position after
homing completion
Summary of Contents for ALPHA5 Smart
Page 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Page 2: ......
Page 4: ...ii...
Page 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Page 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Page 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Page 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Page 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Page 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Page 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Page 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Page 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Page 635: ......