(1) Basic homing profile (equivalent to homing profile 1 of FALDIC-
α
Series)
Described here is the homing profile of the most basic motion, in which homing is started, the
reference signal for homing (deceleration starting signal) is detected and deceleration to the creep
speed for homing occurs, and the reference signal for shift operation is detected and movement by
the home position shift unit amount is caused until the motion is stopped.
Use the profile if the machine stopping position is less than the reference signal for homing
(deceleration starting signal) or reference signal for shift operation.
Because nOT nor -OT is installed for homing of a rotating body as an indicator of the
traveling limit, this homing profile is used in principle.
[Parameter setting example]
PA1_
No. Name
Setting
Default
value
Change
01 Control mode selection
6: Extension mode
0
Power
PA2_
No. Name
Setting
Default
value
Change
06 Homing speed
500.00 [r/min]
500.00 Always
07 Creep speed for homing
50.00 [r/min]
50.00
Always
08 Starting direction for homing
0: Forward rotation
0
Power
09
Reverse traveling unit amount
for homing
0 [units]
0
Always
10
Homing direction after reference
signal detection
0: Forward rotation
0
Power
11
Reference signal for shift
operation
1: Encoder Z-phase
1
Power
12
Reference signal for homing
(Deceleration starting signal)
0: Home position LS
0
Power
13
Home position LS signal edge
selection
0: Rising edge
0
Power
14 Home position shift unit amount 1000 [units]
1000
Always
15
Deceleration operation for creep
speed
0: Reverse rotation is
disabled
0 Power
16
Home position after homing
completion
0 [units]
0
Always
17 Home position detection range
0: Always ON after
homing completion
0 Always
18
Deceleration time at OT during
homing
100.0 [ms]
100.0
Always
24
Selection of operation at OT
during homing
0: Reverse rotation
0
Power
To cancel homing upon detection of +OT or -OT, specify 1 (stop) to parameter PA2_24
(selection of operation at OT during homing).
Summary of Contents for ALPHA5 Smart
Page 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Page 2: ......
Page 4: ...ii...
Page 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Page 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Page 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Page 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Page 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Page 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Page 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Page 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Page 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Page 635: ......