CHAPTER 14 PC LOADER
14-26
Detail Description of Function
14
Automatic calculation of electronic gear
Press the "Mechanical settings calulation" button at [PA1: Basic setting] to open a special window.
Enter specifications of each mechanical system to automatically calculate the electronic gear.
Automatic calculation of workpiece inertia ratio
Press the "Enter vibration suppressing resonance frequency" at [PA1: Control gain and filter
setting] and enter the anti resonance frequency and resonance frequency* to automatically
calculate the workpiece inertia ratio.
* The resonance frequency is not the one suppressed with the notch filter.
Perform servo analyze to check this resonance frequency.
This resonance frequency appears as a set with the anti resonance frequency, and the value is
about twice the anti resonance frequency.
[Example of resonance frequency]
Anti-resonance frequency: about 45Hz
Resonance frequency: about 90Hz
Gain
Frequency [Hz]
Summary of Contents for ALPHA5 Smart
Page 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Page 2: ......
Page 4: ...ii...
Page 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Page 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Page 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Page 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Page 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Page 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Page 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Page 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Page 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Page 635: ......