CHAPTER 13 RS-485 COMMUNICATIONS
Modbus RTU Communications
13-15
13
<Response message example>
Station No.
1byte
01
FC
1byte
17
No. of data bytes 1byte
0C
00
・・・
Feedback speed: 1000 [r/min] (3E8h)
00
03
Data 1
4byte
E8
00
・・・
Effective torque: 80 [%] (50h)
00
00
Data 2
4byte
50
00
・・・
Motor current: 80 [%] (50h)
00
00
Information
Data 3
4byte
50
19
CRC check
16 bits
(2 bytes)
5F
FC 08h (Echo back maintenance )
(1) Query from the master
Station No.
1 byte
FC 1
byte
・・・
08h
(H)
Sub code
2 bytes
(L)
・・・
Specify
0000h
as the sub code of echo back.
(H)
Information
Data
2 bytes
(L)
・・・
Specify an arbitrary data.
(L)
CRC check
16 bits
(2 bytes)
(H)
(2) Response message from the amplifier
Station No.
1 byte
FC 1
byte
・・・
08h
(H)
Sub code
2 bytes
(L)
・・・
0000h
(H)
Information
Data
2 bytes
(L)
・・・
Echo back the specified data.
(L)
CRC check
16 bits
(2 bytes)
(H)
Summary of Contents for ALPHA5 Smart
Page 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Page 2: ......
Page 4: ...ii...
Page 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Page 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Page 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Page 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Page 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Page 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Page 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Page 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Page 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Page 635: ......