CHAPTER 2 WIRING
Description of I/O Signals
2-89
2
CONT Through: Sequence Output Signal (Setting value 91 to 95)
This function allows communications input signals to be output via OUT signals of the hardware.
Function
The signals set to CONT 20 to 24 can be output through OUT signals 1 to 3 of the hardware. When
a CONT
□
signal is allocated to an OUT signal, the ON/OFF status of the CONT signal is output
as a through signal to the OUT signal regardless of the function allocation of the corresponding
CONT signal.
CONT signals respectively correspond to CONT a to e
Corresponding CONT signals
CONTa CONT20
CONTb CONT21
CONTc CONT22
CONTd CONT23
CONTe CONT24
Parameter
setting
Set the values (91 to 95) corresponds to the parameter of output terminal function setting. The
setting values to the relevant signals are as follows.
PA3_51 to 53
No. Name
Setting
range
Change
51
OUT1 signal assignment
52
OUT2 signal assignment
53
OUT3 signal assignment
0 to 95 91 : CONTa through
92 : CONTb through
93 : CONTc through
94 : CONTd through
95 : CONTe through
Power
Summary of Contents for ALPHA5 Smart
Page 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Page 2: ......
Page 4: ...ii...
Page 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Page 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Page 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Page 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Page 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Page 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Page 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Page 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Page 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Page 635: ......