CHAPTER 10 PERIPHERAL EQUIPMENT
10-4
Cable Size
10
10.2.1 Main Circuit Section Cable Size
The following cable sizes are recommended for parts (1), (2), (3) and (4) specified on page 10-2.
Single-phase
200
V
Recommended cable size [mm
2
]
(1) Power supply (L1,L2,L3)
(3) Motor power (U,V,W)
(4) Earthing (E)
(2) Regenerative resistor
(RB1, RB2, RB3)
Rated
rotation
speed
[r/min]
Capacity
[kW]
75[
℃
]
(HIV)
90[
℃
]
(CV)
75[
℃
]
(HIV)
90[
℃
]
(CV)
3000
0.05
to
0.75
0.5
2000
0.75
1500 0.5
1.25 0.75 1.25
0.75