CHAPTER 2 WIRING
Encoder
2-19
2
Catch
2.4.2 Encoder Cable
To fabricate the encoder cable by yourself, take care of the following.
Do not install a relaying terminal block between the servo amplifier and motor.
Use a shielded cable.
Connect the shielded cable with the designated connector pin, connector shell or cable clamp on
both sides.
The servo amplifier communicates with the encoder built in the servomotor through high speed
serial communications.
The shield treatment is important for the assurance of reliability of serial communications.
The maximum encoder wiring length is 50 m.
When twisting the cable, combine the following pair of signals.
P5 and M5, SIG+ and SIG-, BAT+ and BAT- (See the sample connection diagrams on pages 2-6
and 2-8.)
Please notice that wrong wiring may cause the encoder or battery trouble.
Perform shield treatment at the encoder according to the procedure specified below.
Despite motor capacity, wiring treatment at the servo amplifier is the same.
Encoder cable preparation method
[1] Peel off the end of the shield about 15 mm.
Fold back the shield.
Wind copper foil tape two or three turns around the shield.
[2] Solder the wiring to the connector.
The shrink tube wrapping each element cable
assures safety.
[3] Fix the connector to the shell cover.
[4] Bend the shield to fix.
[5] While aligning the catches on both sides, fit the
shell cover.
[6] Align the position of the catch to the mold cover to
fix.
Connect the end of the shielding wire on
the motor side to pin no.3.
Relay the shielding wire with a lead wire
of AWG#22 to 26 and then crimp the
wire to the connector pin.
Servo amplifier side
Motor side
Summary of Contents for ALPHA5 Smart
Page 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Page 2: ......
Page 4: ...ii...
Page 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Page 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Page 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Page 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Page 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Page 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Page 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Page 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Page 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Page 635: ......