CHAPTER 5 SERVO ADJUSTMENT
Profile Operation
5-27
5
Rotation direction
Moving
distance
Operation
frequency
Acceleration
time
Deceleration
time
Rotation
speed
Timer
Go stroke
Return
stroke
P20 Continuous P37
P38
P21 P22
P23
How to stop profile operation
Profile operation is stopped by the user or upon an error*.
* The error includes the following events.
±OT, EMG or external regenerative resistor overheat is detected in the middle.
The free-run (BX) signal is turned on in the middle.
The servo-on (S-ON) signal is turned off in the middle.