CHAPTER 15 APPENDIXES
Capacity Selection Calculation
15-29
15
Constants
■
200 V series
Series
Capacity
[kW]
Inertia
10
-4
[kg·m
2
]
Capacity of capacitor
[
μ
F]
0.2 0.24
440
0.4 0.42
660
GYB
0.75 1.43
1360
1.0 6.26
1.5 8.88
2.0 12.14
1360
3.0 17.92
1800
4.0 39.99
2400
5.5 51.44
GYH
7.0 63.52
4000
0.5 7.96
0.75 11.55
1.0 15.14
1.5 22.33
1360
GYG
2000 r/min
2.0 29.51
1800
0.5 11.55
0.85 15.15
1360
GYG
1500 r/min
1.3 22.33
1800
0.1 0.0577
0.2 0.213
440
0.4 0.408
660
0.75 1.21
1.0 3.19
1.5 4.44
1360
GYC
2.0 5.69
1800
0.05 0.0192
0.1 0.0371
0.2 0.135
440
0.4 0.246
660
0.75 0.853
1.0 1.73
1.5 2.37
1360
2.0 3.01
1800
3.0 8.32
2400
4.0 10.8
GYS
5.0 12.8
4000
Summary of Contents for ALPHA5 Smart
Page 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Page 2: ......
Page 4: ...ii...
Page 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Page 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Page 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Page 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Page 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Page 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Page 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Page 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Page 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Page 635: ......