CHAPTER 2 WIRING
2-36
Description of I/O Signals
2
OFF
Parameter
setting
If the torque limit signal is assigned to a sequence input terminal, specify the corresponding value
("19" or "20") to the input terminal function setting parameter.
If the torque limit signal is not assigned to the sequence input terminal, the settings of PA1_27
(forward rotation torque limit) and PA1_28 (reverse rotation torque limit) are always enabled.
Relevant
description
(1) Torque limit detection signal
This signal is turned on while the output torque of the servomotor is equal to or larger than the
torque limit.
The torque limit detection output is enabled in all control modes.
To assign the torque limit detection to a sequence output terminal, specify the corresponding
value ("26") to the output terminal function setting parameter.
Immediate value continuation: Sequence input signal (Reference value 22)
Positioning motion can be continued according to the next data from the target position (speed) started
in the immediate value mode.
This function is enabled only if “7” (positioning operation) is selected for parameter PA1 01.
Function
After immediate value operation starts with the first data, supply desired data in an immediate
value continuation command. Operation continues with the next data, following execution of the
first data.
OFF
Immediate value
continuation
completion
Time
Start positioning
OFF
Immediate value
continuation
OFF
Immediate value
continuation
permission
OFF
ON
In-position (level)
ON
Command position (Initial startup position)
(Position to be continued)
Command speed
(Initial startup speed)
(Speed to be continued)
ABS/INC
(ABS/INC) (ABS/INC)
(Initial startup position)
(Position to be continued)
Rotaion speed
50 ms
(Permitted again after data continuation)
Summary of Contents for ALPHA5 Smart
Page 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Page 2: ......
Page 4: ...ii...
Page 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Page 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Page 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Page 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Page 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Page 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Page 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Page 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Page 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Page 635: ......