CHAPTER 6 KEYPAD
6-26
Monitor Mode
6
(26) Settling time (displayed digits: unsigned five digits)
The settling time under position control is displayed.
The displaying range is from 0 to 1000.0 ms. If the settling
time exceeds 1000.0 ms, "1000.0 is displayed.
(27) Resonance frequency 1 (displayed digits: unsigned four digits)
The resonance frequency recognized by the servo
amplifier is displayed.
The displaying range is from 50 to 2000 Hz. If no
resonance is detected, "4000" is displayed.
(28) Resonance frequency 2 (displayed digits: unsigned four digits)
The resonance frequency recognized by the servo
amplifier is displayed.
The displaying range is from 50 to 2000 Hz. If no
resonance is detected, "4000" is displayed.
on26
SET
(1 sec. or over)
1
----
000.0
Blinks three times.
Blinks three times.
----
SHIFT
ESC
ESC
on27
2000
ESC
SET
(1 sec. or over)
on28
2000
ESC
SET
(1 sec. or over)
U
L
/
Summary of Contents for ALPHA5 Smart
Page 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Page 2: ......
Page 4: ...ii...
Page 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Page 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Page 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Page 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Page 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Page 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Page 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Page 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Page 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Page 635: ......