CHAPTER 13 RS-485 COMMUNICATIONS
Modbus RTU Communications
13-23
13
a) Hardware CONT signal (CONT1 - 5)
00h
00h
00h
Data
4bytes
0 0 0
CONT5 CONT4 CONT3 CONT2
CONT1
b) Hardware OUT signal (OUT1 - 3)
00h
00h
00h
Data
4bytes
0 0 0 0 0
OUT3
OUT2
OUT1
(2) Control mode, Sequence mode, Alarm at present, Alarm history
Each piece of data in the control mode, sequence mode, alarm at present, and alarm history is the
code data of 1 byte.
00h
00h
00h
DATA
4bytes
Code
The content of the code varies depending on the data. For the detail, refer to the corresponding
tables below.
Control mode
Sequence mode
Code Control
mode Code
Sequence mode
00h Position
control
00h
Servo off
01h
Speed control
01h
Servo on
02h
Torque control
02h
Zero speed stop
03h
Manual feed (JOG)
04h
Pulse operation
05h
+
OT
06h
-
OT
07h
In LV (under voltage)
08h
Positioning
09h
Homing
0Ah
Interrupt positioning
Alarms at present and alarm histories
Summary of Contents for ALPHA5 Smart
Page 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Page 2: ......
Page 4: ...ii...
Page 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Page 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Page 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Page 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Page 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Page 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Page 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Page 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Page 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Page 635: ......