Point detection, area 1: Sequence output signal (Reference value 17)
Point detection, area 2: Sequence output signal (Reference value 18)
The current position of the servomotor is detected and output in these signals.
This function is enabled after homing or position preset.
Function
Three types of the output format can be selected through settings of PA2_31 (point detection, area
detection).
The signal can be output at two points with point detection, area 1 and 2.
(1) PA2_31 (point detection, area detection) = 0: point detection
The signal is turned on near the position specified with PA2_32 (point detection, area detection 1)
or PA2_33 (point detection, area detection 2).
(2) PA2_31 (point detection, area detection) = 1: ON for positive side
The signal is turned on at a position beyond the setting of PA2_32 (point detection, area detection
1) or PA2_33 (point detection, area detection 2).
The signal is turned off below the setting.
(3) PA2_31 (point detection, area detection) = 2: ON for negative side
The signal is turned on below the setting of PA2_32 (point detection, area detection 1) or PA2_33
(point detection, area detection 2).
The signal is turned off beyond the setting.
Parameter
setting
To assign point detection and area 1 to a sequence output terminal, specify the corresponding
value ("17") to the output terminal function setting parameter. Specify ("18") for point detection and
area 2.
190.0 200.0 210.0
OFF
ON
190.0 200.0 210.0
OFF
ON
10.0 10.0
190.0 200.0 210.0
Current position
OFF ON
Point detection
PA2_32: Point detection, area detection position 1
PA2_33: Point detection, area detection position 2
PA2_34: Point detection range
PA2_32: Point detection, area detection position 1
PA2_33: Point detection, area detection position 2
Current position
Area
PA2_32: Point detection, area detection position 1
PA2_33: Point detection, area detection position 2
Current position
Area
Summary of Contents for ALPHA5 Smart
Page 1: ...24C7 E 0016c FUJI SERVO SYSTEM ALPHA5 Smart USER S MANUAL...
Page 2: ......
Page 4: ...ii...
Page 36: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0...
Page 276: ...CHAPTER 4 PARAMETER 4 108 Output Terminal Function Setting Parameter 4...
Page 368: ...CHAPTER 6 KEYPAD 6 56 Test Operation Mode 6...
Page 392: ...CHAPTER 7 MAINTENANCE AND INSPECTION 7 24 Troubleshooting 7...
Page 472: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Page 488: ...CHAPTER 12 POSITIONING DATA 12 16 Response Time 12...
Page 592: ...CHAPTER 14 PC LOADER 14 48 Parameter Conversion Tool 14 1 2 3 4 6 7 8 9 10 11...
Page 633: ...CHAPTER 15 APPENDIXES Product Warranty 15 41 15 15 9 Product Warranty...
Page 634: ...CHAPTER 15 APPENDIXES 15 42 Service Network 15 15 10 Service Network...
Page 635: ......