CHAPTER 9 CHARACTERISTICS
Timing Chart
9-3
9
9.1.2 Each Signal Timing
Sequence input signal response time
The response time from sequence signal activation to signal recognition inside the servo amplifier
is 2 ms. Leave the sequence input signal turned on for at 1 ms or more.
[Example] Deviation clear signal
Deviation clear (50)
OFF
ON
Position deviation amount
pulses
2 ms
Zero deviation (23)
OFF
ON
0 pulses
OFF
Pulse command
Can be input
May not be input
Can be input
2 ms
CONT signal
(sequence input signal)
OFF
ON
Recognition by servo
amplifier
OFF
ON
2 ms