NOTIFICATON
At the occurrence of a type of error for which the checkbox DETECT is ticked, the
COLLECTED ERROR STATE flag is set at the same time. Additionally the FAULT
indicator light on the front panel of the controller lights, the FAULT relay opens
and a signal sound.
HOLD
Detected types of errors for which the checkbox HOLD is ticked are stored.
Sporadic errors are indicated until the corresponding HOLD checkbox is
unchecked.
LOG
CONTROLS
ROUTER
DEVICE
CONNECTED
CAN connection between Controller and Router broken.
MEMORY
Memory error.
WATCHDOG
Watchdog error of the device. This error type is logged conforming to standards,
press the CLEAR button to reset the error.
FIRMWARE
The firmware version is not compatible with the IRIS-Net version used. A firmware
update is recommended.
POWER SUPPLY
Error in the power supply of the device.
DSP
Error in the digital signal processing (DSP) of the device.
HARDWARE
Hardware error.
PG / LT
TEMPERATURE
Temperature overload of the device.
GPI SUPERVISED
Voltage at supervised GPI out of range.
AMP INPUTS
PILOT DETECTION x-
IN1
Missing pilot tone at input 1 of cluster A or B.
PILOT DETECTION x-
IN2
Missing pilot tone at input 2 of cluster A or B.
PILOT DETECTION A-
S1
Missing pilot tone at spare input 1 of cluster A.
PILOT DETECTION B-
S2
Missing pilot tone at spare input 2 of cluster B.
MASTER
COMBINED FAULT
STATE
The FAULT indicator light on the front panel of the device lights at the occurrence of this type
of error.
Manually setting or resetting an error.
IRIS-Net
PAVIRO | en 968
Bosch Security Systems B.V.
User Manual
2017.05 | 3.20 | F.01U.119.956