/IDX50
hipass xover frequency
20 to 20000
Hz
/IDX51
lopass xover type
0 to 17
0 = off, 1 = butter6, 2 = s12q05, 3 = s12q06, 4 = s12q07, 5
= s12q08, 6 =
s12q10, 7 = s12q12, 8 = s12q15, 9 = s12q20, 10 =
bessel12, 11 = butter12, 12
= linkwz12, 13 = bessel18, 14 = butter18, 15 = bessel24, 16
= butter24, 17 = linkwz24
/IDX52
lopass xover frequency
20 to 20000
Hz
/IDX53
FIR filter bypass
0 / 1
0 = active, 1 = bypass
/IDX54
FIR filter
max. 41
characters
read only
/IDX55
polarity
0 / 1
0 = Normal, 1 = Invertiert
/IDX56
mute
0 / 1
0 = ON, 1 = MUTE
/IDX57
level
-128 to +6
dB
/IDX58
level trim
-30 to +6
dB
/IDX59
limiter bypass
0 / 1
0 = ON, 1 = BYPASS
/IDX5A
limiter type
0 to 4
0 = user, 1 = hi, 2 = mid, 3 = lo, 4 = sub
/IDX5B
limiter threshold
+11 to +71
dBu at amp output
/IDX5C
limiter attack time
0 to 50
milliseconds
/IDX5D
limiter release time
10 to 999
milliseconds
/IDX5E
config type
0 to 15
binary LED pattern
/IDX5F
config description
max. 18
characters
/IDX60
input channel name
max. 30
characters
/IDX61
thermo limiter bypass
0 / 1
0 = ON, 1 = BYPASS
/IDX62
thermo limiter setting
set of 12 values whitespace separated complete list of values in the order:
r_vc c_vc r_m c_m z brms ctime atime rtime t_max t_wall
t_knee
IRIS-Net