UPTIME
Shows the uptime of the amplifier (standby not included) since the last reset of the Event Log.
For further details about the amplifiers's Event Log please refer to the owner's manual.
MAINS VOLTAGE
Shows the mains voltage and the mains current consumption.
IP ADDRESS
Shows the IP address of the remote module‘s primary interface. The IP address of the secondary
interface can be seen in the OMNEO page.
MAC ADDRESS
Shows the MAC address of the remote control modul's primary interface. The MAC address of the
secondary interface is one number higher and can be seen in the OMNEO page.
Amplifier Setup
Element
Default
Range
Description
GAIN/
SENSITIVITY
GAIN/SENSITIVITY displays the amplifiers gain or input sensitivity.
IMPORTANT NOTE: A RCM-28 firmware update with version V2.0.10
or higher will enable the Sensitivity switch on the amplifier rear
panel. Please make sure that the Sensitivity switches of all
amplifiers in your system are set correctly. In previous firmware
versions the amplifier gain was fixed to +35 dB if a RCM-28 module
was installed.
POWER DELAY
Object No. *
150 ms
50...6350 ms
50 ms Steps
Allows programming an amplifier’s power-on delay. Setting different
delay times is recommended to prevent the mains fuse from blowing
when powering on several amps at the same time.
BREAKER
Show the current setting of the amplifier's Mains Circuit Breaker
Protection. For further details about this protection please refer to
the owner's manual.
INPUT SELECT
Analog
Analog, AES/
EBU, OMNEO
Allow selecting the audio input to be amplified. The analog audio
input (ANALOG), the digital audio input (AES/EBU) or the OMNEO
audio input are available.
HINT: The value of the property “AudioInput” corresponds to the
currently used audioinput. You can write the value “ANLG” to this
property to select the analog audioinput. You can write the value
“AES” to this property to select the digital audioinput. You can
write the value “NET” to this property to select the OMNEO
networkinput.
BREAKIN
Analog
Analog, AES/
EBU, Auto
Allows selecting the audio input of the amplifier to be output via the
two OMNEO audio network Tx channels. The analog audio input
(Analog) or the digital audio input (AES/EBU) are available. Select
Auto to output the digital audio signal and switch from digital input to
analog input automatically if the digital input signal is not OK.
Digital Input
IRIS-Net
REMOTE AMPLIFIER | en 250
Bosch Security Systems B.V.
User Manual
2017.05 | 3.20 | F.01U.119.956