General Parameters
Element
Default
Range
Description
ms
ms, samples,
ft, in, mtr,
cm, µs, s
This lets you select the unit of measurement for the delays.
0 °Celsius
-20 to 60 °C
-4 to 140 °F
Entering the actual ambient temperature is possible here. In case you have
chosen a distance value as unit of measurement for the delay, delay times
are corrected in relation to temperature. Temperatures can be entered as
°C or °F.
Editing Delays by ”Dragging the Mouse” in the Graphics Display
The graphics display shows the corresponding speaker symbol in color as soon as a delay has been activated. Clicking
with the left mouse button onto the speaker icon and keeping the mouse button pressed allows dragging the symbol to
the right or the left, which results in a change of the selected channel’s delay time. A delay’s title is shown black as
soon as the mouse cursor is positioned on top of the corresponding icon to provide improved overview and handling.
OUTPUT PARAMETRIC EQ
All output channels employ 6-band parametric equalizers each, mainly for speaker equalization. Except for the
possibility to select ”All pass” as filter type, these filters are identical to the ones of the input EQ's.
The Output Parametric EQ is selected by clicking on the eight block (PEQ) of the flow diagram selector or on the
SPEAKER PROCESSING PEQ block in the full-scale flow diagram.
IRIS-Net
DIGITAL SOUND PROCESSOR | en 675
Bosch Security Systems B.V.
User Manual
2017.05 | 3.20 | F.01U.119.956